• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.102.2012.tde-28022013-104203
Document
Author
Full name
Monica Faria de Almeida Prado
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Caram, Rosana Maria (President)
Dornelles, Kelen Almeida
Labaki, Lucila Chebel
Title in Portuguese
Conforto térmico nos edifícios das indústrias de calçados de Jaú
Keywords in Portuguese
Ambientes industriais
Conforto ambiental
Conforto térmico
Desempenho térmico
Estratégias passivas
Galpões fabris
Indústrias de calçados
Sensação térmica
Abstract in Portuguese
Este trabalho aborda o desempenho térmico obtido em edifícios industriais do setor calçadista, perante a importância em obter condições ambientais favoráveis à execução das atividades através de uma arquitetura adequada ao contexto climático. Assim, o objetivo nesta pesquisa é avaliar as condições de conforto térmico oferecidas pelos edifícios das indústrias calçadistas do município de Jaú, um importante pólo industrial do setor no interior de São Paulo. Caracterizam-se as tipologias construtivas dos edifícios quanto à geometria, materiais e sistema de ventilação. As estratégias passivas para obtenção de conforto térmico nos galpões fabris são identificadas e avaliadas utilizando as recomendações presentes na NBR 15220. Para avaliar as condições de conforto térmico, foram medidas as variáveis ambientais, sendo que a temperatura foi analisada sob condições de aceitabilidade térmica, conforme estabelecido pela ASHRAE 55-2010. Para estimar a sensação térmica dos usuários, são utilizados os índices PMV e PPD. Também foi aplicado um questionário para verificar o nível de satisfação dos funcionários com o ambiente de trabalho. Os resultados apontam que a maioria dos edifícios apresenta uma tipologia semelhante, com geometria retangular e ventilação realizada através de esquadrias nas fachadas. A ausência de diversas estratégias passivas resulta em um edifício com baixa inércia térmica e vulnerável às condições climáticas externas, sendo que em períodos quentes a temperatura interna foi superior a 30ºC, e em períodos frios inferior a 15ºC. A sensação térmica dos usuários na maior parte do período do expediente corresponde ao desconforto térmico para o calor, principalmente no período vespertino, sendo que a porcentagem de insatisfeitos ultrapassa 80%. Deste modo, há necessidade de otimizar a adoção de estratégias passivas, para proporcionar melhores condições térmicas de trabalho. Para isto, são indicadas soluções simples, que propiciam melhorias ao desempenho térmico dos edifícios, exemplificando: o uso de sistemas que possibilitem o resfriamento evaporativo e ampliação das áreas de aberturas destinadas à ventilação do edifício.
Title in English
Thermal comfort in footwear industry from Jaú
Keywords in English
Environment comfort
Factory sheds
Industrial environments
Passive strategies
Shoes industries
Thermal comfort
Thermal performance
Thermal sensation
Abstract in English
This paper discusses the thermal performance obtained in industrial buildings in the footwear sector, given the importance of obtaining favorable environmental conditions for the execution of activities through an architecture suited to the climate context. Thus, the objective of this research is to evaluate the thermal comfort conditions provided by the buildings of the footwear industries of Jaú city, an important industrial pole. It is characterized the typologies of building's construction regarding its geometry, materials and ventilation system. The passive strategies for achieving thermal comfort in the factory sheds are identified and evaluated using the recommendations present in the NBR 15220. To evaluate the thermal comfort conditions it was measured the environmental variables, and the temperature was examined under conditions of thermal acceptability, as established by ASHRAE 55-2010. In order to estimate the thermal sensation of the users, the PMV and PPD indices were used. Also, a questionnaire was applied in order to check the level of employee satisfaction with the working environment. The results show that most of the buildings presents a typology similar with a rectangular geometry and ventilation obtained through frames at the facades. The absence of different passive strategies results in a building with a low thermal inertia and vulnerable to the external weather conditions, and in hot periods, the internal temperature was above 30°C, and during colder periods it was lower than 15°C. The thermal sensation of users in most of the period of the working shift matches the thermal discomfort to the heat, especially in the afternoon, and the percentage of discontentment exceeds 80%. This way, there is a need to optimize the adoption of passive strategies, to provide better thermal conditions of work. For this purpose, simple solutions that provide improvements to the thermal performance of buildings are given, examples: the use of systems which allows evaporative cooling and expansion of openings areas for the ventilation of the building.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Monicac.pdf (17.29 Mbytes)
Publishing Date
2013-04-02
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.