• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2019.tde-30052019-164145
Documento
Autor
Nombre completo
Rodrigo Massayuki Magori
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2018
Director
Tribunal
Barbosa, Marcello Henrique Nogueira (Presidente)
Garcia, Flávio Luís
Salim, Rodrigo
Santos, Marcel Koenigkam
Título en portugués
Reprodutibilidade da medida tomográfica da versão dos componentes femoral e acetabular após artroplastia total do quadril
Palabras clave en portugués
Artroplastia total de quadril
Femoral
Reprodutibilidade
Versão acetabular
Resumen en portugués
Contexto: O objetivo do estudo foi avaliar a reprodutibilidade intra e interobservador da versão acetabular e femoral da prótese total de quadril. Materiais e métodos: estudo prospectivo incluindo 101 indivíduos submetidos a prótese total de quadril, sendo 114 quadris desde 2008, com imagens de tomografia computadorizada incluindo os componentes acetabular e femoral da prótese e os côndilos femorais. Resultados: Para avaliação intraobservador o coeficiente de correlação interclasse foi para o observador A de 0.99 para versão acetabular e femoral com intervalo de confian- ça (IC) de 0.98-1.00, para o observador B de 0.98 para versão acetabular (IC de 0.97- 0.99) e de 0.88 para versão femoral (IC de 0.83-0.92), para o observador C de 0.98 para versão acetabular (IC de 0.97-0,99) e de 0.83 para versão femoral (IC de 0.76-0.88). Para avaliação interobservador o coeficiente de correlação interclasse foi calculado com as medidas da primeira leitura de cada observador e em seguida da segunda leitura, sendo a primeira leitura da versão acetabular de 0.99 (IC de 0.98-1.00), a segunda leitura da versão acetabular de 0.99 (IC de 0.98-1.00), a primeira leitura da versão femoral de 0.99 (IC de 0.98-1.00), a segunda leitura da versão femoral de 0.96 (IC de 0.94-0.97). Conclusão: Com os resultados obtidos, podemos concluir que as medidas tomográficas de versão acetabular possuem excelente reprodutibilidade tanto inter quanto intraobservador, as medidas de femoral possuem excelente reprodutibilidade interobservador e de boa a excelente reprodutibilidade intraobservador.
Título en inglés
Reproducibility of femoral and acetabular version of total hip arthroplasty measured using computed tomography
Palabras clave en inglés
Acetabular version
Femoral
Reproducibility
Total hip arthroplasty
Resumen en inglés
Context: The objective of the study was to evaluate the reproducibility intra e interobserver of acetabular and femoral version after total hip arthroplasty. Materials and methods: prospective studying including 101 individuals after total hip arthroplasty, 114 hips since 2008, with computed tomography images including the components of acetabular and femoral prothesis and the femoral condyle. Results: intra-observer coefficient of interclass correlation was 0.99 for observer A for acetabular and femoral version (IC of 0.98-1.00), for B 0.98 for acetabular version (IC of 0.97-0.99) and 0.88 for femoral version (IC of 0.83-0.92), for C 0.98 for acetabular version (IC of 0.97-0.99) and 0.83 for femoral version (IC of 0.76-0.88). For inter-observer evaluation, the interclass correlation coefficient was calculated with the measurements of the first reading of each observer and the second reading, the first reading of the acetabular version was 0.99 (IC of 0.98-1.00), the second reading of the acetabular version was 0.99 (CI 0.98-1.00), the first reading of the femoral version was 0.99 (CI of 0.98-1.00), the second reading of the femoral version was 0.96 (CI of 0.94- 0.97). Conclusion: With the results obtained, we can conclude that the tomographic measurements of acetabular version have excellent inter- and intraobserver reproducibility, femoral measurements have excellent interobserver reproducibility and good to excellent intraobserver reproducibility.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-08-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.