Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2017.tde-12122017-111539
Document
Auteur
Nom complet
Edson Batista de Mello
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1998
Directeur
Jury
Oliveira, Vilma Alves de (Président)
Joaquim, Marcelo Basílio
Mascarenhas, Nelson Delfino d'Ávila
Titre en portugais
Restauração de imagens médicas utilizando o filtro de Kalman
Mots-clés en portugais
Filtro de Kalman 2-D
Modelos AR
Restauração de imagens
Resumé en portugais
Neste trabalho técnicas de restauração de imagens aplicadas à filtragem de imagens médicas foram estudadas. Considera-se uma abordagem recursiva de filtragem e suas diversas implementações em duas dimensões. A implementação utilizada neste trabalho foi a do filtro de Kalman de atualização reduzida (RUKF). Na implementação do filtro de Kalman de atualização reduzida um quarto de plano (QP) foi tomado como região de suporte e um modelo autoregressivo bidimensional (AR 2-D) foi utilizado como modelo de imagem. Os parâmetros do modelo AR 2-D e a variância do ruído foram encontrados através de uma implementação do algoritmo de Levinson para duas dimensões baseada no algoritmo de Levinson em configuração multicanal. A ordem do modelo AR 2-D foi determinada pelo critério de informação de Akaike (AIC). Para análise de resultados o filtro de Kalman de atualização reduzida foi aplicado em uma imagem planar, considerada invariante no espaço e com ruído ele observação não estacionário, e os resultados comparados àqueles obtidos com o filtro de Wiener.
Titre en anglais
not available
Mots-clés en anglais
2-D Kalman filter
Image restoration
Models AR
Resumé en anglais
In this work image restoration techniques for the filtering of medicai images are studied. Emphasis is given to the recursive approach to image restoration and its different implementations are described. The implementation used in the restoration procedure is the reduced update Kalman filter (RUKF). In the implementation of the reduced update Kalman filter a quarter plane is adopted as the region of support and a 2-D autoregressive (AR) model is used as the image model. The parameters of the 2-D AR model and the variance of the driving noise are found by a 2-D implementation of the Levinson algorithm. The model order of the 2-D AR model is determined by the Akaike information criterion (AIC). For the analysis of the results, the reduced update Kalman filter is applied to a space invariant plane image with nonstationary noise. The results are compared to the results of the Wiener filter.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-12-12
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.