• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2014.tde-19012015-100324
Document
Auteur
Nom complet
Paulo Marcos Faria Maciel
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2014
Directeur
Jury
Sabogal Paz, Lyda Patrícia (Président)
Franco, Regina Maura Bueno
Moruzzi, Rodrigo Braga
Titre en portugais
Remoção de Giardia spp. e Cryptosporidium spp. em águas de abastecimento com turbidez elevada utilizando cloreto de polialumínio: estudo em escala de bancada e desafios analíticos
Mots-clés en portugais
C. parvum
Cryptosporidium spp.
Giardia spp.
Cloreto de polialumínio – PAC
Jarteste
Separação imunomagnética – IMS
Tratamento de água
Resumé en portugais
O objetivo deste trabalho foi avaliar o desempenho da remoção de cistos deGiardia spp. e oocistos de Cryptosporidium parvum, em águas de abastecimento com turbidez elevada, em experimentos em escala de bancada (coagulação, floculação, decantação e filtração). Para tanto, empregou-se o coagulante cloreto de polialumínio – PAC. O método de filtração em membranas foi adotado para a concentração de protozoários, seguido ou não da etapa de purificação por separação imunomagnética – IMS. Os métodos foram avaliados em experimentos de controle de qualidade analítica e o método sem IMS apresentou as seguintes porcentagens de recuperação, 80% ±16,32% para cistos de Giardia spp. e 5% ±10,00% para oocistos de C. parvum. O método com IMS apresentou 31,5%±7,55% de recuperação para cistos de Giardia spp. e 5,75%±3,20% de recuperação para oocistos de C. parvum. Os experimentos demonstraram que não houve melhora na remoção de ambos os protozoários na condição de maior dosagem de coagulante (65 mg.L-1 de PAC e pH 7,29). A condição de menor dosagem de coagulante (25 mg.L-1 de PAC e pH 6,76) apresentou um desempenho melhor, ao contrário de uma expectativa de que a maior dosagem de coagulante pudesse favorecer a remoção destes microrganismos. A condição de menor dosagem apresentou, na água filtrada, 50 e 75% de ausência de identificação de cistos de Giardia e oocistos de C. parvum, respectivamente. A condição de maior dosagem apresentou (oo)cistos na água filtrada de todas amostras analisadas. Estes resultados indicam a importância do controle da coagulação na remoção de protozoários.
Titre en anglais
Giardia spp. Cysts and Cryptosporidium spp. Oocysts removal in high turbid drinking water using polyaluminum chloride: a bench scale study and analytical challenges
Mots-clés en anglais
C. parvum
Cryptosporidium spp.
Giardia spp.
Bench scale
Drinking water treatment
Immunomagnetic separation – IMS
Polyaluminum chloride – PACl
Resumé en anglais
The aim of this study was to evaluate the performance of Giardia spp. cysts and Cryptosporidium parvum oocysts removal in a bench scale experiment. The coagulant polyaluminium chloride – PACl was used in this research. The protozoa concentration tests were performed by applying the Membrane Filtration method, with and without Immunomagnetic Separation assay-IMS. The methods were evaluated using control experiments and the method without IMS had the following percentage recovery, 80% ± 16.32% and 5% ±10.00% for Giardia cysts and C. parvum oocysts, respectively. The method with IMS presented 31.5% ± 7.55% and 5.75% ± 3.20% of percentage recovery for Giardia cysts and C. parvum oocysts, respectively. Bench scale experimental results have clearly shown that there was no improvement in protozoa removal using the superior dosage of coagulant. The inferior dosage condition (25 mg.L-1 of PACl and pH 6,76) performed better, which was contrary to what was expected in which a superior dosage of coagulant could favour when removing microorganisms. The inferior dosage condition presented 50% and 75% of absence of Giardia cysts and C. parvum oocysts in the final water, respectively. The second coagulation condition (65 mg.L-1 of PACl and pH 7,29) presented protozoa (oo)cysts in the final water of all the samples examined. These results indicate the importance of coagulation control in protozoa removal.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-01-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.