Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2016.tde-29082016-092248
Document
Auteur
Nom complet
Fabio José Coletti
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2003
Directeur
Jury
Daniel, Luiz Antonio (Président)
Nour, Edson Aparecido Abdul
Giansante, Antonio Eduardo
Piveli, Roque Passos
Povinelli, Jurandyr
Titre en portugais
Inativação de microrganismos indicadores presentes em efluentes secundários de esgoto sanitário com radiação ultravioleta
Mots-clés en portugais
Actinometria
Desinfecção
Microrganismos indicadores
Modelo de Hom
Radiação ultravioleta
Radiometria
Resumé en portugais
Nesta pesquisa estudou-se o emprego de radiação ultravioleta em reatores de batelada e em reator com escoamento contínuo (unidade comercial de alta intensidade), respectivamente em escala de laboratório e real. Os ensaios em batelada tiveram como finalidade monitoramento da potência radiante da lâmpada de baixa pressão de vapor de mercúrio durante a vida útil, determinação da intensidade média de radiação ultravioleta incidente no interior da câmara de desinfecção, obtenção dos coeficientes do modelo de Hom para coliformes totais, Escherichia coli e Clostridium perfringens e comparação da resistência à desinfecção desses microrganismos indicadores e colifagos. Os ensaios em sistema contínuo apresentaram como principal objetivo estudo da resistência dos microrganismos indicadores à desinfecção em condições de operação em escala real. Nos ensaios de desinfecção utilizou-se esgoto sanitário tratado em nível secundário. Os microrganismos indicadores apresentaram a seguinte ordem decrescente de resistência à desinfecção: C. perfringens, coliformes totais, E. coli e colifagos. As percentagens de inativação de C. perfringens, coliformes totais, E. coli e colifagos nos ensaios em batelada variaram de 0 a 99,882%, 36,3 a 99,999%, 21,8 a 100% e de 86,5 a 100%, respectivamente. Os resultados de inativação obtidos para coliformes totais e E. coli apresentaram ajustes pelo modelo de Hom com valores de R2 superiores a 0,81 e 0,76, respectivamente. Comprovou-se que a instalação contínua é inadequada para efluentes com elevadas concentrações de sólidos em suspensão e matéria orgânica.
Titre en anglais
Inactivation of indicator microorganisms presents in secondary effluents of wastewater with ultraviolet radiation
Mots-clés en anglais
Actinometry
Disinfection
Hom model
Indicator microorganisms
Radiometry
Ultraviolet radiation
Resumé en anglais
In this research the use of ultraviolet radiation was studied in batch and continuous flow (high intensity commercial unit) reactors, respectively in laboratory and real scale. The batch assays were aimed to monitor the wattage of the low-pressure mercury lamp during its lifetime, to determine the mean ultraviolet radiation intensity inside disinfection chamber, to obtain Hom model coefficients for total coliforms, Escherichia coli and Clostridium perfringens and to compare the resistance to disinfection of these indicator microorganisms and coliphages. The assays in the continuous system presented as main objective to study the resistance of these indicator microorganisms to disinfection in real scale operational conditions. In the disinfection assays wastewater treated by a secondary level was used. The indicator microorganisms presented the following decreasing order of disinfection resistance: C. perfringens, total coliforms, E. coli and coliphages. C. perfringens, total coliforms, E. coli and coliphages inactivation percentages in batch assays varied from 0 to 99,882%, 36,3 to 99,999%, 21,8 to 100% and from 86,5 to 100%, respectively. The inactivation results obtained for total coliforms and E. coli presented adjustments by Hom model with R2 values above 0,81 and 0,76, respectively. It was proved that the installation of high intensity is not adequate for effluents with high concentration of suspended solids and organic matter.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-08-29
 
AVERTISSEMENT: Le matériau se réfère à des documents provenant de cette thèse ou mémoire. Le contenu de ces documents est la responsabilité de l'auteur de la thèse ou mémoire.
  • COLETTI, F. J., DANIEL, L. A., e POVINELLI, Jurandyr. Pós-tratamento por lodos ativados de efluentes provenientes de processos anaeróbios de tratamento de esgoto sanitário: determinação de constantes cinéticas. In XIX Congresso Brasileiro de Engenharia Sanitária e Ambiental, Foz do Iguacú, 1997. XIX Congresso Brasileiro de Engenharia Sanitária e Ambiental.Foz do Iguaçu - PR, 1997.
  • COLETTI, F. J., POVINELLI, Jurandyr, e DANIEL, L. A. Pós-tratamento de efluentes de tratamento anaeróbio por lodos ativados. In SIMPOSIO INTERNAZIONALE DI INGENERIA SANITARIA AMBIENTALE, Ravello, 1997. SISISA.RAVELLO, ITALIA, 1997.