• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2016.tde-24052016-153057
Documento
Autor
Nombre completo
Nágila Ali Mustafá
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Machado, Manoel Eduardo de Lima (Presidente)
Medeiros, João Marcelo Ferreira de
Santos, Marcelo dos
Título en portugués
Fadiga cíclica flexural de instrumentos Hyflex CM e TF Adaptive em diferentes situações experimentais
Palabras clave en portugués
Curvatura
Fadiga cíclica
Fratura
Níquel-titânio
Resumen en portugués
O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel- titânio, Hyflex CM (Coltène, EUA) e TF Adaptive (SybronEndo, EUA) em diferentes situações experimentais. Todas as limas que foram selecionadas possuíam conicidade 0,04 e diâmetro de ponta 35. Utilizou-se um dispositivo desenvolvido especificamente para realizar o ensaio flexural dinâmico. Os instrumentos TF Adaptive foram divididos em 3 grupos de acordo com o ângulo de curvatura do ensaio: 45º, 60º e 90º e cada grupo subdividido em 2 subgrupos de acordo com o tipo de movimento: rotação contínua e Adaptive. Cada subgrupo era composto por 15 instrumentos TF Adaptive, totalizando 90 instrumentos. Quinze instrumentos Hyflex CM formavam o grupo 4, no ensaio com ângulo de curvatura 90 graus e rotação contínua. A simulação foi realizada em canais artificiais de aço com ângulo de 45, 60, 90 graus e raio 5m m. O número de ciclos e o tempo em segundos até a fratura foram tabulados e analisados. Entretanto, a fadiga cíclica flexural foi significante maior nos três grupos em movimento Adaptive. E as limas TF Adaptive em seu próprio movimento tiveram maior número de ciclos e tempo até a fratura quando comparadas as Hyflex CM no ensaio de 90 graus. Portanto, conclui-se que o sistema Adaptive (limas TF Adaptive + movimento Adaptive) foi mais seguro à resistência á fadiga flexural, e no ensaio de 90 graus o sistema Adaptive foi mais resistente quando comparado com as limas Hyflex CM no movimento de rotação contínua.
Título en inglés
Flexural cyclic fatigue of instruments Hyflex CM and TF Adaptive in diferente experimental situations
Palabras clave en inglés
Curvature
Cyclic fatigue
Fracture
Nickel-titanium
Resumen en inglés
The aim of this work to evaluate the cyclic fatigue resistance flexural the instruments of nickel-titanium, HyFlex CM (Coltène, USA) and TF Adaptive (SybronEndo, USA) in different experimental situations. All files that were selected had 0.04 taper and tip diameter 35. We used a device developed specifically to perform the dynamic flexural test. The TF Adaptive instruments were divided into 3 groups according to the angle of curvature of the test: 45, 60 and 90 and further divided in two subgroups according to the type of movement: continuous rotation and Adaptive. Each group consisted of 15 instruments TF Adaptive totaling 90 instruments. Fifteen HyFlex CM instruments formed the group 4 in the trial of bend angle 90 degrees and continuous rotation. The simulation was performed in artificial steel angled channels 45, 60, 90 degrees and radius 5m m. The number of cycles and the time in seconds until fracture were tabulated and analyzed. However, the cyclical flexural fatigue was significantly greater in the three groups Adaptive motion. And the TF Adaptive files on your own movement had a higher number of cycles and time to fracture when the HyFlex CM compared in 90-degree test. Therefore, it is concluded that the adaptive system (TF Adaptive Motion + Adaptive files) was safer resistance to flexural fatigue, and 90 degrees test Adaptive system is more resistant when compared with the HyFlex files into continuous.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-06-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.