Thèse de Doctorat
DOI
https://doi.org/10.11606/T.3.2009.tde-18122009-131117
Document
Auteur
Nom complet
Ricardo de Freitas Fernandes Pontes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Teixeira, Antonio Carlos Silva Costa (Président)
Guirardello, Reginaldo
Gut, Jorge Andrey Wilhelms
Moraes, José Ermírio Ferreira de
Paiva, José Luis de
Titre en portugais
Modelagem e síntese ótima de rede de reatores de processos oxidativos avançados para o tratamento de efluentes.
Mots-clés en portugais
Efluentes
Oxidação (processos)
Reatores químicos
Resumé en portugais
Substâncias tóxicas como o fenol e outros compostos aromáticos dificultam o tratamento de efluentes via digestores biológicos. Estes compostos tóxicos em altas concentrações são nocivos aos lodos biológicos, podendo inviabilizar por completo o tratamento. Nas últimas décadas, os Processos Oxidativos Avançados (POAs), como os processos Fenton e foto- Fenton, surgiram como alternativa para o tratamento de compostos tóxicos. Os POAs degradam os compostos orgânicos pela geração de compostos oxidantes fortes, como o radical hidroxila, a partir de reagentes como peróxido de hidrogênio. Os processos Fenton e foto-Fenton fazem uso de ferro (II), um catalisador relativamente barato, para catalisar a decomposição do peróxido de hidrogênio, reação denominada como reação de Fenton. Em virtude dos complexos mecanismos presentes nos processos Fenton e foto-Fenton, torna-se necessária uma compreensão da cinética do processo, que envolve reações térmicas e fotoquímicas, por meio de sua modelagem matemática fenomenológica. A modelagem da degradação do fenol via processos Fenton e foto-Fenton proposta por este trabalho começa pela estequiometria dos dois processos, que descreve as reações químicas, térmicas e fotoquímicas existentes. A partir destas, é possível desenvolver o modelo cinético dos processos Fenton e foto-Fenton, no qual se determina a velocidade com que estas reações ocorrem. O passo seguinte é o da modelagem hidráulica (ou de escoamento) dos reatores de processo Fenton e foto-Fenton, sendo que para o segundo processo, o modelo deve levar em conta a propagação da radiação por dentro de reator. Foram realizados 3 experimentos de degradação de fenol via processo Fenton para análise das variações das concentrações de fenol, catecol e hidroquinona. Os dados experimentais são comparados com resultados simulados com intuito do ajuste das constantes cinéticas do modelo. Com as constantes ajustadas, são realizadas comparações entre os processos Fenton e foto-Fenton para análise de suas eficiências. A partir dos modelos matemáticos dos reatores de processos Fenton e foto-Fenton, é desenvolvido um modelo de otimização baseado em superestrutura de redes de reatores para a síntese de uma planta de tratamento de efluentes contaminados com fenol. Objetivou-se a redução dos custos de capital, operação e depreciação desta planta, sujeitos às restrições de projeto e ao modelo da superestrutura, resultando em modelos de programação não-linear inteira mista. Foram geradas soluções ótimas para o tratamento de efluentes contaminados com fenol em redes de um, dois e três reatores de POAs.
Titre en anglais
Modelagem e síntese ótima de rede de reatores de processos oxidativos avançados para o tratamento de efluentes.
Mots-clés en anglais
Fenton process
Mathematical modeling
Mixed integer nonlinear programming
Parameter estimation
Photo-Fenton process
Process synthesis
Reactor network
Wastewater treatment
Resumé en anglais
Toxic substances such as phenol and other aromatic compounds make the wastewater treatment by biological (aerobic or anaerobic) digestors more difficult. These toxic compounds in high concentrations are harmful for the biological sludge and they may render the treatment impractical. In recent decades, Advanced Oxidative Processes (AOPs) appeared as an alternative for the treatment of toxic compounds. AOPs degrade the organic compounds by generating strong oxidizing compounds, such as the hydroxyl radical, from reactants such as hydrogen peroxide. The Fenton and photo-Fenton processes make use of iron (II), a relatively inexpensive catalyst, to catalyze the hydrogen peroxide decomposition, reaction known as the Fenton reaction. Because of the complex nature of the mechanisms that take place in the Fenton and photo-Fenton processes, the understanding of the process kinetics, which involves thermal and photochemical reactions, becomes necessary through its first-principle mathematical modeling. The modeling of phenol degradation by the Fenton and photo-Fenton processes proposed in this work starts with the stoichiometry of the two processes that enumerates the existing thermal and photochemical reactions. Furthermore, it is possible to develop the Fenton and photo- Fenton kinetic model, which determines the reaction rates. The next step is to model the hydraulic (or flow) behavior of the Fenton and photo-Fenton process reactor, whereas the model for the latter must consider how the radiation propagates inside the reactor. Three experiments of the phenol degradation by the Fenton process were carried out to analyze the concentration variation for phenol, catechol and hydroquinone. The experimental data are compared with simulated results aiming the estimation of the kinetic constants of the model. Using the adjusted constants, the Fenton and photo-Fenton processes were compared to analyze their efficiencies. From the mathematical models of the Fenton and photo-Fenton process reactors, an optimization model based on reactor network superstructure is developed for the synthesis of a phenol contaminated wastewater treatment plant. The objective is to minimize the plant capital, operation and depreciation costs, subject to design constraints and to the superstructure model, thus resulting in mixed integer nonlinear programming models. Optimal solutions were generated for the phenol contaminated wastewater treatment in networks with one, two and three AOP reactors.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.