Doctoral Thesis
DOI
https://doi.org/10.11606/T.3.2011.tde-03042012-120210
Document
Author
Full name
Gilberto Nery de Araújo Neto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Helene, Paulo Roberto do Lago (President)
Fernandes, Juliana Ferreira
Figueiredo, Enio José Pazini
Lima, Maryangela Geimba de
Santos, Josemir Coelho
Title in Portuguese
Contribuição ao desenvolvimento de técnicas de monitoramento remoto para blocos de fundação de edifícios em concreto armado com vistas à durabilidade.
Keywords in Portuguese
Estrutura de concreto (monitoramento; durabilidade)
Abstract in Portuguese
Durante muito tempo as estruturas de concreto foram consideradas livres de manutenção, ou seja, estruturas quase eternas a menos que fossem sobrecarregadas ou destruídas intencionalmente ou por acidente. Esse pensamento caiu por terra nas últimas décadas quando várias estruturas de concreto começaram a apresentar problemas degradando-se bem mais rápido que o esperado. O monitoramento estrutural nasceu da necessidade de acessar a condição de segurança de uma estrutura de forma mais rápida, precisa e com o benefício de criar uma base de dados sobre a estrutura monitorada. O monitoramento de edifícios ainda é um assunto pouco abordado nas pesquisas e publicações. O alto custo agregado às pontes, viadutos e outras grandes estruturas atraem o interesse de pesquisadores e fabricantes de equipamentos. O problema escolhido como alvo no monitoramento a ser desenvolvido foi a degradação de blocos de fundações em concreto armado com reação álcali-agregado (RAA) pela dificuldade de acesso em inspeções. Uma simulação da expansão causado por RAA em concreto foi desenvolvida para experimentos com sensores e técnicas de monitoramento de fundações. No experimento foram testadas aplicações de strain gauges na armadura, na superfície através de um long gauge adaptado e LVDTs (linear variable differential transformer) aplicados na superfície. A ancoragem dos long gauges não suportou o esforço, impedindo a correta avaliação do sensor. Os LVDTs têm grande potencial para acompanhar o desenvolvimento de fissuras, mas sofrem depois de alguma expansão, pois se desalinham com a superfície do concreto. Os strain gauges aplicados na armadura mostraram boa relação com a expansão medida e têm grande potencial no monitoramento. O processo de decisão e projeto do monitoramento para os blocos é explicado e definido. Uma proposta de aplicação do conceito de estrutura tolerante a dano aos blocos de fundação com RAA é dada para otimização de planos de manutenção e intervenções.
Title in English
Contribution to the development of techniques to remote monitoring for foundation building blocks in concrete with a view to durability.
Keywords in English
Foundation monitoring
Structural durability
Structural monitoring
Abstract in English
For a long time, concrete structures were considered "maintenance-free", i.e. quasi eternal, unless they were overloaded or destroyed intentionally or by accident. This thought has been reconsidered in recent decades when several concrete structures began to present problems and degraded much faster than expected. Structural monitoring has been originated from the need to access the safety condition of a structure more quickly, accurately and with the benefit of creating a database of the structure monitored. The high cost related to bridges, overpasses and other large structures still attracts the interest of researchers and equipment manufacturers. However, the monitoring of buildings is still a subject rarely addressed in research and publications. The problem chosen to be addressed in this research is the degradation of reinforced concrete foundation blocks by alkali-aggregate reaction (AAR) due to difficult access during inspections and unpredictable development of the problem. A review on the sensors available on the market and on monitoring techniques used in other structures with the problem was undertaken. A simulation of the AAR`s expansion in concrete has been developed for an experiment with sensors and monitoring techniques of foundations. In this experiment, strain gauges were applied on the reinforcing bars and adapted on a long gauge on the surface. LVDTs (linear variable differential transformer) were also applied on the surface. The anchoring of the long gauges did not support the applied tension, preventing a correct evaluation of the sensor. LVDTs have great potential to monitor the development of cracks, but after the concrete suffering some expansion, they get misaligned with the surface. The strain gauges used in the armor showed a good relation with the expansion and have great potential in monitoring. The whole decision and design process for the structural health monitoring (SHM) for AAR attacked foundation blocks is explained and the project is defined. A proposal of a damage-tolerant approach for the block is given for optimization of maintenance and interventions.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.