Tesis Doctoral
DOI
https://doi.org/10.11606/T.43.1999.tde-20022014-152226
Documento
Autor
Nombre completo
Marco Aurelio Lisboa Leite
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1999
Director
Tribunal
Dietzsch, Olacio (Presidente)
Fauth, Anderson Campos
Hamburger, Ernst Wolfgang
Shellard, Ronald Cintra
Silva, Ruy Pepe da
Título en portugués
Calorímetro de Líquidos Nobres para Radiações de Alta Energia
Palabras clave en portugués
Alta energia
Calorimetria
Líquidos Nobres
Resumen en portugués
Este trabalho descreve a construção e testes de um calorímetro eletromagnético de criptônio liquido utilizando uma geometria projetiva na forma de acordeom para os absorvedores eletrodos. Testes do calorímetro com feixes de elétrons de energia entre 20 e 200 GeV, realizados na linha de feixe H4 do acelerador SPS do CERN, apontam para uma resolução em energia de 5.63/(E[GeV] )0.26)% e uma não linearidade integral máxima de +/- 0,3%. O calorímetro é dividido longitudinalmente em 3 seções, sendo a primeira altamente segmentada transversalmente em uma direção, formando um pre-shower integrado ao calorímetro. A posição de incidência da partícula no calorímetro pode ser determinada com uma resolução de 2.16/(E[GeV] )0,19 7.93 / E[GeV])mm no pre-shower e o ângulo de incidência da partícula (utilizando a informação de posição das outras seções) com uma resolução de (32.01/(E[GeV] ) 0.95 44 /E[GeV])mrad. Os sinais do calorímetro permitem a realização de medidas de tempo com uma resolução de 290ps com elétrons de 120 GeV. Também são apresentados e discutidos o efeito da presença de material inativo na resolução em energia, a resposta do calorímetro a múons e os resultados da comparação entre simulações de Monte Carlo com medidas feitas com feixes de partículas. Por fim, é feito um estudo comparativo da resolução em energia obtida com este calorímetro e com um calorímetro de argônio liquido de geometria semelhante.
Título en inglés
Noble Liquid Calorimeter High-energy Radiation
Palabras clave en inglés
Calorimetry
High energy physics
Noble liquids
Resumen en inglés
This work describes the construction and tests of a liquid krypton electromagnetic calorimeter employing an accordion shaped projective geometry for the absorbers and electrodes. The tests of the calorimeter using electron beams of energy ranging from 20 to 200 GeV and a muon beam of 225 GeV, from the H4 beam line of the CERN SPS, showed an energy resolution of 5,63/(E[GeV] ) 0.26)% and a maximum integral non-linearity of +/- 0.3%. the calorimeter is divided longitudinally in 3 sections, the first one being highly segmented on the transversal direction, operating as a pre-shower integrated on the calorimeter. The position of incidence for a particle in the calorimeter can be determined with a resolution of (2.16/E[GeV] 0.19 7.93 /E[GeV])mm on the pre-shower and the angle of incidence (using the position information from all sections) with a resolution of (32.01/E[GeV] 0.95 44 /E[GeV])mrad. The calorimeter signal allow timing measurements to be performed with a resolution of 290ps for 120 GeV electrons. It is also presented and discussed the energy resolution behavior in the presence of dead material in front of the calorimeter, the calorimeter response to muons and the comparison between the results from data and Monte Carlo calculations. Finally, it is presented a comparative study between the energy resolution of this calorimeter and a liquid argon calorimeter employing a similar accordion shaped geometry.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.