• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.46.2014.tde-19012015-141648
Documento
Autor
Nombre completo
Fernando Silva Lopes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Gutz, Ivano Gebhardt Rolf (Presidente)
Carvalho, Alexandre Zatkovskis
Isolani, Paulo Celso
Jesus, Dosil Pereira de
Masini, Jorge Cesar
Título en portugués
Hifenização da eletroforese capilar com sistema eletroquímico em fluxo: desenvolvimento de instrumentação para a determinação de íons metálicos com pré-concentração eletroquímica e para o estudo da oxidação de alcoóis
Palabras clave en portugués
Eletroanalítica
Eletroforese capilar
Instrumentação
Metais (determinação)
Oxidação de alcoóis
Tratamento de amostras
Resumen en portugués
Um sistema completo foi desenvolvido para o novo acoplamento de uma célula eletroquímica em fluxo com um eletroforese capilar equipado com detector condutométrico sem contato (EC-CE-C4D). Este acoplamento compreendeu o design da interface EC-CE, um potenciostato protegido contra fuga de alta tensão, subsistema de controle de fluxo por bombas solenóide e um equipamento CE-C4D adaptado para a aplicação. Um software dedicado para aquisição de dados, controle e operação do sistema foi desenvolvido na ferramenta gráfica de programação LabView. O sistema foi inicialmente aplicado na eletrodeposição de traços dos metais Cd2+, Pb2+, Cu2+, Zn2+ e Tl+, seguida pela redissolução e separação destes por CE, o que resultou em fator de pré-concentração de até 55 vezes para todos os metais, exceto Zn2+. Os metais acumulados foram redissolvidos na matriz original da amostra para permitir a separação e determinação conjunta com cátions majoritários (p. ex. alcalinos e alcalinos terrosos e amônio, se acima do LD). Para amostras cuja matriz possa causar interferência, pouco antes da injeção no CE, foi realizado processo de cleanup pela redissolução dos metais no eletrólito de separação. Experimentos pra separação bidimensional com o potencial de deposição ou redissolução voltamétrica como primeira dimensão e o tempo de eletromigração como segunda dimensão foram propostos e demonstrados. A oxidação eletroquímica de espécies orgânicas na interface EC-CE surgiu como um segundo campo de aplicação para: a) derivatização de analitos neutros tornando-os carregados ou ionizaveis, p. ex., conversão de álcoois alifáticos de cadeia curta em carboxilatos que possam ser separados e quantificados por CE-C4D; b) investigação/monitoramento de processos de eletrodo pela detecção de produtos carregados ou ionizáveis de reação de eletrodo, p. ex., investigação de condições experimentais para eletrooxidação de glicerol objetivando-se a síntese de produtos com maior valor comercial.
Título en inglés
Hyphenation of capillary electrophoresis with an electrochemical flow system: development of instrumentation aiming metallic ions determination by electrochemical preconcentration and study of alcohols oxidation
Palabras clave en inglés
Alcohols oxidation
Capillary electrophoresis
Electroanalysis
Instrumentation
Metals (determination)
Sample treatment
Resumen en inglés
A complete instrumental system was developed for the new coupling of an electrochemical flow cell to capillary electrophoresis with contactless conductivity detection (EC-CE-C4D) and comprising an innovative design of the EC-CE interface, a potentiostat circuit protected from high voltage leakages, a solenoid pump based flow management subsystem, and a CE-C4D equipment tailored for this application. Dedicated software for data acquisition, devices control and operation automation was developed in LabVIEW graphical programming tool. The system was first applied to the electrodeposition of traces of Cd2+, Pb2+, Cu2+, Zn2+ and Tl+ , followed by stripping and separation by CE, allowing a 55-fold preconcentration factor in 6 min for all metals but Zn2+. The accumulated metals were stripped into the original sample matrix to allow their separation together with the sample's major cations (e.g. alkaline and alkaline earth metals and ammonium, if above LOQ). For samples with a matrix that originates interferences, cleanup was achieved by stripping the metals into background electrolyte shortly before injection in the capillary. Two-dimensional separations with voltammetric deposition or stripping potential as one dimension and electromigration time as the second one were proposed and demonstrated. Electrochemical oxidation of organic species in the EC-CE interface emerged as a second field of application for: a) derivatization of neutral analytes into charged or ionizable species, e.g., conversion of short chain aliphatic alcohols into carboxylates that can been determined by CE-C4D; b) investigation/monitoring of electrode processes by detection of charged or ionizable reaction products of electrode reactions, e.g., investigation of experimental conditions for glycerol electro-oxidation aiming the synthesis of commercially valuable products.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-02-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.