Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2005.tde-10102014-095907
Documento
Autor
Nombre completo
Marco Aurelio Santos Cordeiro
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2005
Director
Tribunal
Rochitte, Carlos Eduardo (Presidente)
Cesar, Luiz Antonio Machado
Coelho, Otavio Rizzi
Nussbacher, Amit
Spadaro, Joel
Título en portugués
Angiografia coronária não-invasiva por meio de tomografia computadorizada: determinação da acurácia de sistema isotrópico com 32 colunas de detectores em pacientes com doença arterial coronariana avançada
Palabras clave en portugués
Coronariopatia/diagnóstico
Diagnóstico por imagem
Doenças cardiovasculares/diagnóstico
Resumen en portugués
A doença arterial coronária (DAC) avançada caracteriza-se pela presença de vasos calcificados e difusamente estenosados, o que reduz a acurácia da angiografia coronária não-invasiva por meio dos atuais aparelhos de tomografia computadorizada (CT) com 16 colunas de detectores (16-MDCTA). O principal objetivo deste estudo foi tentar demonstrar uma acurácia diagnóstica global de pelo menos 90% para a detecção de estenoses coronárias >= 50% em pacientes com DAC avançada e alta probabilidade de possuírem escores de cálcio coronário elevados, mediante a utilização de um sistema de CT com 32 colunas de detectores, todas capazes de adquirir simultaneamente cortes com 0,5 mm de espessura (32x0,5-MDCTA). Angiografias coronárias sincronizadas ao traçado de ECG foram obtidas por meio da 32x0,5-MDCTA (32 cortes de 0,5 mm, voxels isotrópicos de 0,35x0,35x0,35 mm³, rotação do gantry a 400 ms) em 30 pacientes consecutivos (25 do sexo masculino, com idade média igual a 59±13 anos e índice de massa corpórea médio de 26,2±4,9 Kg/m²) e portadores de DAC avançada. As principais artérias nativas, incluindo seus ramos de primeira ordem com diâmetro >= 1,5 mm bem como os enxertos coronários existentes, foram avaliados de forma independente quanto à presença de estenoses >= 50%. Os stents foram excluídos. As angiografias coronarianas convencionais (realizadas em média 18±12 dias antes das respectivas 32x0,5-MDCTAs) foram analisadas de maneira quantitativa (angiografia coronária quantitativa). A mediana do escore de cálcio de Agatston foi igual a 510 (variação entre 3 e 5066). A sensibilidade, a especificidade e os valores preditivos positivo e negativo para a detecção de estenoses >= 50% nas artérias coronárias nativas foram seguintes: 76% (29/38), 94% (190/202), 71% (29/41), e 96% (190/199), respectivamente. A acurácia diagnóstica global foi de 91% (219/240). Do total de vasos analisados, 20% (69/352) foram excluídos devido à existência de um dos seguintes artefatos: movimento, ruído e baixo realce do contraste radiológico isoladamente ou em conjunto (45/69 ou 65%), distorção da imagem secundária à presença de eletrodo de desfibrilador ou marcapasso (18/69 ou26%), e calcificação arterial excessiva (6/69 ou 9%). Conclui-se que a 32x0,5-MDCTA exclui com precisão as estenoses coronarianas >= 50% em pacientes com DAC avançada e escore de cálcio coronário elevado, com acurácia diagnóstica global de 91%
Título en inglés
Noninvasive coronary angiography by computed tomography: assessment of the accuracy of an isotropic system with 32 detector rows in patients with advanced coronary artery disease
Palabras clave en inglés
Cardiovascular diseases/diagnosis
Coronary disease/diagnosis
Diagnostic imaging
Resumen en inglés
Advanced coronary artery disease (CAD) is characterized by calcified and diffusely stenotic vessels, hampering accuracy of noninvasive coronary angiography with current 16-detector computed tomography (CT) scanners. The main purpose of this study was to try to demonstrate an overall diagnostic accuracy of at least 90% for detection of coronary stenoses >= 50% by half-millimeter 32-detector CT angiography (32x0.5-MDCTA) in patients with advanced CAD and a high likelihood of having elevated coronary calcium scores. ECG-gated coronary 32x0.5-MDCTA (32x0.5 mm cross-sections, 0.35x0.35x0.35 mm³ isotropic voxels, 400 ms gantry rotation) was performed in 30 consecutive patients (25 male, 59±13 years-old, 26.2±4.9 Kg/m²) with advanced CAD. Major coronary arteries, including >=1.5-mm first order branches, and bypass grafts were independently evaluated for >= 50% stenoses. Stents were excluded. Conventional coronary angiography (performed on average 18±12 days before their corresponding 32x0.5-MDCTAs) was analyzed by quantitative coronary angiography. Median Agatston calcium score was 510 (3-5066 range). Sensitivity, specificity, positive and negative predictive values for detection of >= 50% stenoses in the native coronary arteries were: 76% (29/38), 94% (190/202), 71% (29/41), and 96% (190/199), respectively. Overall diagnostic accuracy was 91% (219/240). Twenty percent (69/352) of the vessels were excluded from the analysis due to one of the following artifacts: motion, noise, and low contrast enhancement isolated or in combination (45/69 or 65%), image distortion secondary to an ICD or pacemaker lead (18/69 or 26%), and severe arterial calcification (6/69 or 9%). We concluded that 32x0.5-MDCTA accurately excludes >= 50% coronary stenoses in patients with advanced CAD and high calcium scores, showing an overall diagnostic accuracy of 91%
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-10-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.