• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2012.tde-20122012-114110
Document
Auteur
Nom complet
Marcony Rodrigues de Santhiago
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
José Junior, Newton Kara (Président)
Lira, Rodrigo Pessoa Cavalcanti
Maia, Mauricio
Siqueira, Wallace Chamon Alves de
Yamamoto, Joyce Hisae
Titre en portugais
Análise de qualidade óptica e performance visual em olhos implantados com lentes intraoculares asféricas neutras
Mots-clés en portugais
Aberrometria
Catarata
Facoemulsificação
Lentes intraoculares
Resumé en portugais
Objetivo: Determinar se o implante de uma determinada lente intraocular asférica resulta em redução das aberrações oculares e melhora da qualidade ótica e sensibilidade ao contraste sem que ocorra redução critica da profundidade de foco. Desenho: Estudo prospectivo, duplo-cego, randomizado. Métodos: Este estudo que incluiu 25 pacientes com catarata bilateral, uma LIO asférica foi implantada em um olho e uma LIO esférica no olho contralateral. Aberrações de maior ordem e parâmetros de qualidade ótica foram obtidos através de aberrômetro de retinoscopia dinâmica, 1 e 3 meses apos a cirurgia. Foi também medido a acuidade visual com e sem correção e a sensibilidade ao contraste. Acuidade visual para perto e distancia intermediaria foi obtida como forma de medida da profundidade de foco. Resultados: Não houve diferença estatisticamente significativa entre os grupos para acuidade visual corrigida e não corrigida 1 e 3 meses apos a cirurgia. Houve diferença estatisticamente significativa entre os grupos quanto a sensibilidade ao contraste sob condições fotópticas na frequência espacial de 12 ciclos por grau e sob condições mesópicas em todas as frequências espaciais estudadas. O grupo com a LIO Akreos AO obteve menores valores de aberrações de maior ordem totais e de aberração esférica com pupilas de 5 e 6 mm e melhores valores de qualidade ótica comparado ao grupo com LIO Akreos Fit (p <0.05). Não houve diferença significativa entre os grupos quando se investigou visão de perto e intermediaria corrigido para longe. Conclusões: A LIO asférica Akreos AO induziu menos aberrações de maior ordem além de produzir melhores parâmetros de qualidade ótica com melhores resultados de sensibilidade ao contraste em condições mesópicas sem redução critica de profundidade de foco quando comparado a LIO esférica Akreos Fit.
Titre en anglais
Implantation of an aspherical intraocular lens
Mots-clés en anglais
Aberrometry
Cataract
Intraocular lenses
Phacoemulsification
Resumé en anglais
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved optical quality and contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil and optical quality parameters were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distancecorrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at 1 and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils and better optical quality parameters compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity under mesopic conditions and optical quality parameters were better with the Akreos AO with similar results of depth of focus.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-01-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.