Master's Dissertation
DOI
https://doi.org/10.11606/D.54.1985.tde-01092014-112539
Document
Author
Full name
Washington Luiz de Barros Melo
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1985
Supervisor
Committee
Sanches, Rosemary (President)
Jordao, Jose Alberto Rodrigues
Roda, Valentin Obac
Title in Portuguese
Espectropolarimetro computadorizado : nova maneira de obtenção da atividade ótica
Keywords in Portuguese
Discroismo circular
Dispersão óptica rotatória
Espectrômetro computadorizado
Abstract in Portuguese
Montamos um espectrômetro o qual nos permite obter dados de atividade ótica Dispersão Rotatória (DRO) e Dicroísmo Circular (DC) simultaneamente. O sistema ótico consiste de uma fonte de luz, um monocromador, um suporte para amostra, um analisador gigante e um detector de luz. O analisador girante é sustentado por um mancal pneumático e gira usando um motor de passo, o qual é controlado por um microcomputador. Um outro motor de passo também controlado por microcomputador é usado para girar a grade de difração do monocromador. Para obter os espectros de DRO e DC, o monocromador pára em um certo comprimento de onda, enquanto o eixo de transmissão do analisador é posicionado em β= 0°, 45°, 90° e -45° relativo ao eixo de transmissão do polarizador. O microcomputador através do detector de luz lê as quatro intensidades de luz e usando um formalismo desenvolvido por nós, relaciona-as à elipticidade e a rotação ótica naquele comprimento de onda. O monocromador é então girado a um novo comprimento de onda e o procedimento é repetido. No final, os espectros de DC e DRO podem ser mostrados em uma Tabela ou com um Gráfico. Além de funcionar como um espectropolarímetro, o equipamento pode ser usado também como um espectrofotômetro, para acompanhar cinética de reação, para medir dicroísmo linear, etc... Devido à relação sinal/ruído, temos nos ângulos medidos, uma resolução de 1º
Title in English
Computerized spectrometer: a new way to obtain optical activity data
Keywords in English
Circular dichroism
Computerized spectrometer
Optical Rotatory Dispersion
Abstract in English
We have assembled a spectrometer which provides the optical activity data Optical Rotatory Dispersion (ORD) and Circular Dichroism (CD) simultaneously. The Optical System consists of a source of light, a monochromator, a polarizer, a sample holder, a rotating analyzer and a light detector. The rotating analyzer is supported by a pneumatic bearing and rotates using a step motor which is controlled by a microcomputer. Another spet motor also controlled by the microcomputer is used to rotate the diffraction grating of the monochromator. To obtain the ORD and CD spectra, the monochromator stops at a certain wave length, while the transmission axis of the analyzer is positioned at β= 0°, 45°, 90° e -45° relative to the transmission axis of the polarizer. The microcomputer through the light detector reads the four light intensities and using the formalism developed by us relates them to the elipticity and optical rotation at that wavelength. The monochromator is then rotated to a new wavelength and the procedure is repeated. At the end the CD and ORD spectra can be shown in a Table or as a graph. Besides functioning as a spectropolarimeter, the equipment can be use also as a regular spectrometer, to follow kinetic of recreations, to measure linear dichroism, etc Due to the signal/noise ratio we have in the measured angles a resolution of 1°
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-09-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.