Doctoral Thesis
DOI
https://doi.org/10.11606/T.59.2014.tde-13012015-224604
Document
Author
Full name
Matheus Manoel Teles de Menezes
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2014
Supervisor
Committee
Naal, Zeki (President)
Seron, Lucia Helena
Demets, Gregoire Jean Francois
Dockal, Edward Ralph
Farias, Robson Fernandes de
Title in Portuguese
Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense
Keywords in Portuguese
cocaína
eletrodos quimicamente modificados
microbalança de cristal de quartzo
química forense
voltametria cíclica
Abstract in Portuguese
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito.
Title in English
Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.
Keywords in English
chemically modified electrodes
cocaine
cyclic voltammetry
forensic chemistry
quartz crystal microbalance
Abstract in English
Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Capacorrigida.pdf (299.03 Kbytes)
Publishing Date
2015-02-10
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.