• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.6.2018.tde-09012018-153633
Documento
Autor
Nombre completo
Maria Ivette Carboni Malucelli
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1991
Director
Tribunal
Niero, Rinaldo (Presidente)
Bacila, Metry
Lucchiari, Pedro Helio
Nogueira, Pericles Alves
Santos, Jair Licio Ferreira
Título en portugués
Método polarográfico na determinação da viabilidade da vacina BCG liofilizada
Palabras clave en portugués
Controle de Qualidade
Vacina BCG Liofilizada
Resumen en portugués
Tendo em vista os vários problemas envolvendo a metodologia correntemente utilizada para a determinação da viabilidade no controle de qualidade da vacina BCG liofilizada, foi levado a efeito um estudo a respeito do assunto. Foi procedido um estudo de métodos alternativos a serem empregados em procedimentos de controle de qualidade da vacina BCG liofilizada. Com esse objetivo foi desenhado e construído um polarógrafo de eletrodo de oxigênio constituído de eletrodo de platina e o de referência de Ag-AgCl embutido em peça única e ainda dotado de sensor de temperatura, com circuito eletrônico permitindo a medida de consumo de oxigênio. Levou-se a efeito, então, estudo comparativo de viabilidade de vacina BCG liofilizada pela medida polarográfica de consumo de oxigênio em comparação à manométrica pelo clássico método de Warburg e o método de contagem de colônias (UFC). A análise de 66 diferentes lotes de vacina BCG liofilizada produzidas pelo Instituto Butantan, São Paulo, e pela Fundação Ataulpho de Paiva, Rio de Janeiro, demonstrou que a técnica polarográfica revelou ser altamente reprodutível e muito mais conveniente que os métodos manométrico e de contagem de colônias. Verificou-se que entre o método polarográfico e o manométrico e UFC os resultados da regressão linear mostraram correlação positiva de alta intensidade e significante ao nível de a= 0,05, permitindo indicar o método polarográfico descrito, como procedimento de escolha para operações de controle de qualidade em laboratórios de produção de vacina BCG bem como em Unidades de Saúde, para determinações adequadas de viabilidade de lotes de vacinas, a serem utilizadas para fins de imunização.
Título en inglés
Polarographic method for determining the viability of the lyophilized BCG vaccine
Palabras clave en inglés
Quality Control
Vaccine Freeze-dried BCG
Resumen en inglés
Considering the several problems regarding the procedures currently employed in the assays o f the control of quality, and the viability of the freeze-dried BCG vaccines, a study on various methods used for this purpose was carried out. Aiming to introduce a much more suitable, sensitive and less time consuming method than the classic Warburg technique and the colony count test (CFU) bacteriological procedure, currently used, a new oxygen electrode polarograph was designed with the aim of employing it for the study of the viability of the freeze-dried BCG vaccine. This polarograph electrode was built in a single piece containing the platinun and theAgAgCl reference electrode besides a temperature sensor. By using this assembly a comparative study was carried on the viability of the freeze-dried BCG vaccine assayed by the polarographic method in comparison with the manometric and the CFU methods. The analysis of the viability of 66 different batches of freeze-dried BCG vaccines produced at the Butantan Institute, São Paulo, and at the Ataulpho de Paiva Foundation, Rio de Janeiro, demonstrated that the polarograpbic technique revealed to be highly reliable and much more convenient than both the manometric and the CFU methods: it has been found out that between the polarographic and the manometric and the CFU, the linear regression sbowed a high intensity positive correlation and significant at the level of a = 0,05. In this way, the polarographic method could be considered as a choice method for the control of quality procedure as well as for the establishment of the viability of the batches of vaccines to be used for human immunization in Units of the Health Department.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-01-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.