• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2019.tde-20032019-145549
Document
Auteur
Nom complet
Renato Rache Gaspar
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2019
Directeur
Jury
Calvo, Wilson Aparecido Parejo (Président)
Karam Junior, Dib
Soares, José Roberto
Titre en portugais
Desenvolvimento do sistema de potência elétrica em uma unidade móvel de irradiação por feixe de elétrons para tratamento de águas residuárias e efluentes industriais
Mots-clés en portugais
acelerador industrial de elétrons
distorção harmônica
qualidade de energia elétrica
unidade móvel de irradiação
Resumé en portugais
O tratamento de águas residuárias e efluentes industriais por irradiação com feixe de elétrons é uma técnica promissora, porém pouco difundida em território Brasileiro. O projeto e a construção de uma unidade móvel contendo um acelerador industrial de elétrons de 700 keV e 20 kW, pelo Instituto de Pesquisas Energéticas e Nucleares (IPEN), é inovador para demonstrar os efeitos e resultados positivos dessa tecnologia. O propósito é deslocar a unidade móvel às diversas empresas com interesse em tratamento dos resíduos líquidos, conectar-se ao sistema elétrico da mesma e iniciar o processo de tratamento por ionização, por meio da irradiação com feixe de elétrons. A conexão da unidade móvel ao sistema elétrico local pode representar um desafio, pela grande diversidade de tensões e distâncias envolvidas, e também pelas grandes injeções de conteúdo harmônico gerado pelo acelerador de elétron que podem afetar as cargas do sistema industrial, comumente sensíveis. Neste trabalho realizou-se uma análise do sistema de potência da unidade móvel, quanto à capacidade de interrupção, seletividade da proteção e níveis de curto-circuito adequados de forma a assegurar uma maior confiabilidade na operação. Ao final, projetou-se e construiu-se o painel elétrico de controle da unidade móvel de irradiação. Além disso, na obtenção de parâmetros operacionais à unidade móvel, realizaram-se simulações e medições no acelerador industrial de elétrons de 1,5 MeV e 37,5 kW, instalado no Laboratório de Fontes Intensas de Radiação, do Centro de Tecnologia das Radiações, as quais demonstraram a necessidade da inserção de um filtro para redução dos índices de distorção nos harmônicos dessa instalação radiativa fixa no IPEN.
Titre en anglais
Developing an electrical power system of a mobile electron beam accelerator to treatment of industrial wastewaters and effluents
Mots-clés en anglais
electric power quality
harmonic distortion
industrial electron accelerator
mobile irradiation unit
Resumé en anglais
The treatment of wastewater and industrial effluents by electron beam irradiation is a promising technique, however, not very widespread in Brazilian territory. The design and a construction of a mobile unit containing an electron beam accelerator of 700 KeV and 20kW, by the Nuclear and Energy Research Institute (IPEN) is innovative to demonstrate the effects and positive results of this technology. The aim is to move the mobile unit to several companies with interest in liquid waste treatment, and connect to the industry electrical system and start the ionization treatment process through electron beam. The mobile unit's connection to the local electrical system can be a challenge in behalf of the great diversity of voltages and distances involved, as well as the large injections of harmonic content generated by the electron beam accelerator that can affect sensitive loads in the industrial system. In this work, an analysis was made of the power system of the mobile unit, regarding interruption capacity, selectivity protection and adequate short circuit levels in order to assure a greater reliability in the operation. At the end, the control panel of the mobile unit, simulations and measurements were carried out at the 1.5 MeV and 37.5 kW electron beam accelerator, installed at the Intensive Radiation Technology Center, which demonstrated the necessity of applying of a filter to reduce the measured harmonic distortion.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2019-04-10
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.