Título en portugués
Desenvolvimento de um simulador antropomórfico para simulação e medidas de dose e fluxo de nêutrons na instalação para estudos em BNCT
Palabras clave en portugués
BNCT
detetor de ativação
simulador antropomórfico
TLDs
transporte de radiação
Resumen en portugués
A instalação do IPEN para pesquisas em BNCT (Terapia por Captura de Nêutrons em Boro) utiliza o canal de irradiação número 3 do reator IEA-R1, no qual tem-se um campo misto de radiação nêutrons e gama. As pesquisas em andamento necessitam que o campo de radiação, na posição de irradiação de amostra, tenha na composição os nêutrons térmicos maximizados e os componentes de nêutrons epitérmicos, rápidos e radiação gama minimizados. Este trabalho foi desenvolvido com o objetivo de avaliar se o campo de radiação atual na instalação é adequado aos trabalhos em BNCT. Para cumprir com este objetivo, uma metodologia para dosimetria de nêutrons térmicos e radiação gama em campos mistos de altas doses, que não era disponível no IPEN, foi implantada no Centro de Engenharia Nuclear do IPEN, utilizando dosímetros termoluminescentes TLDs 400, 600 e 700. Para as medidas de fluxo de nêutrons térmicos e epitérmicos foram utilizados detetores de ativação de ouro aplicando a técnica de razão de cádmio. Um simulador antropomórfico cilíndrico composto de discos de acrílico foi desenvolvido e testado na instalação e para obter valores teóricos do fluxo de nêutrons e a dose ao longo do simulador antropomórfico foi utilizado o código computacional DOT 3.5. Na posição correspondente a aproximadamente metade do comprimento do cilindro do simulador antropomórfico, foram obtidos os seguintes valores: fluxo de nêutrons térmicos (2,52 ± 0,06).108n/cm2s, epitérmicos (6,17 ± 0,26).107n/cm2s, dose absorvida devido a nêutrons térmicos de (4,2 ± 1,8)Gy e devido a radiação gama (10,1 ± 1,3)Gy. Os valores obtidos mostram que os fluxos de nêutrons térmicos e epitérmicos são adequados para os estudos em BNCT, porém, a dose devido a radiação gama está elevada, indicando que a instalação deve ser aprimorada.
Título en inglés
Development of an anthropomorfic simulator for simulation and measurements of neutron dose and flux in the facility for BNCT studies
Palabras clave en inglés
activation detector
anthropomorfic simulator
BNCT
radiation transport
TLDs
Resumen en inglés
IPEN facility for researches in BNCT (Boron Neutron Capture Therapy) uses IEA-R1 reactor's irradiation channel number 3, where there is a mixed radiation field neutrons and gamma. The researches in progress require the radiation fields, in the position of the irradiation of sample, to have in its composition maximized thermal neutrons component and minimized, fast and epithermal neutron flux and gamma radiation. This work was developed with the objective of evaluating whether the present radiation field in the facility is suitable for BNCT researches. In order to achieve this objective, a methodology for the dosimetry of thermal neutrons and gamma radiation in mixed fields of high doses, which was not available in IPEN, was implemented in the Center of Nuclear Engineering of IPEN, by using thermoluminescent dosimeters TLDs 400, 600 and 700. For the measurements of thermal and epithermal neutron flux, activation detectors of gold were used applying the cadmium ratio technique. A cylindrical phantom composed by acrylic discs was developed and tested in the facility and the DOT 3.5. computational code was used in order to obtain theoretical values of neutron flux and the dose along phantom. In the position corresponding to about half the length of the cylinder of the phantom, the following values were obtained: thermal neutron flux (2,52 ± 0,06).108n/cm2s, epithermal neutron flux (6,17 ± 0,26).107.106n/cm2s, absorbed dose due to thermal neutrons (4,2 ± 1,8)Gy and (10,1 ± 1,3)Gy due to gamma radiation. The obtained values show that the fluxes of thermal and epithermal neutrons flux are appropriate for studies in BNCT, however, the dose due to gamma radiation is high, indicating that the facility should be improved.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-08-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.