Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2017.tde-10052017-152745
Document
Auteur
Nom complet
Thais Rodrigues Presutti
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Carvalho, Valdemir Melechco (Président)
Madeira, Marlene de Freitas
Valassi, Helena Panteliou Lima
Titre en portugais
Aplicação da cromatografia a gás associada à espectrometria de massas em tandem no diagnóstico da deficiência de 3β-hidroxidesidrogenase
Mots-clés en portugais
17-hidroxi-pregnenolona
Cromatografia gasosa acoplada a espectrometria de massas em tandem
Extração em fase sólida
Ionização química em modo negativo
Pregnenolona
Resumé en portugais
Pregnenolona (PREG) e 17-alfa-hidroxipregnenolona (17OHPREG) são dois esteroides produzidos pela glândula adrenal e precursores de vários hormônios esteroidais. A dosagem desses compostos tem aplicações clínicas, como o diagnóstico de doenças relacionadas aos corticoesteroides e mineralocorticóides e especialmente na avaliação da atividade da enzima 3-β-hidroxidesidrogenase que é decisiva no diagnóstico de um dos tipos de hiperplasia da glândula adrenal que causa defeitos severos na síntese de esteroides. Métodos cromatográficos associados à espectrometria de massas superaram a especificidade reduzida dos imunoensaios e tem sido crescentemente utilizados na quantificação de esteroides. Os últimos anos tem sido marcados pela hegemonia da cromatografia líquida acoplada à espectrometria de massas em tandem (LC-MS/MS) em grande parte devido à velocidade e possibilidade da análise direta de vários analitos. Porém, no caso específico dos esteroides de tipo 3-hidroxi-5-eno, que apresentam baixa afinidade protônica e, portanto, baixa eficiência de ionização, são necessárias muitas etapas para a conversão em derivados mais detectáveis. Embora desfavorecida em relação ao LC-MS/MS nos últimos anos, a cromatografia gasosa acoplada à espectrometria de massas (CG-MS) apresenta várias características favoráveis para a análise de esteroides como a eficiência cromatográfica ainda insuperável. Adicionalmente, a incorporação da espectrometria de massas em tandem ao CG (CG-MS/MS) torna a técnica tão seletiva quanto LC-MS/MS. No presente trabalho, foi desenvolvido um novo método que permite a extração e derivatização simultâneas da PREG e 17OHPREG de amostras de soro tornando o método de preparo da amostra tão simples quanto os descritos para LC-MS/MS. O método de detecção desenvolvido baseado em ionização química no modo negativo obteve a sensibilidade necessária para o diagnóstico da deficiência da enzima 3-beta-hidroxidesidrogenase utilizando apenas 250 µ:L de amostra.
Titre en anglais
Application of gas chromatography coupled to tandem mass spectrometry in the diagnosis of 3β-hidroxidesidrogenase deficiency
Mots-clés en anglais
17-α-hydroxypregnenolone
Gas chromatography coupled to tandem mass spectrometry
Negative chemical ionization
Pregnenolone
Solid phase extraction
Resumé en anglais
Pregnenolone (PREG) and 17α-hydroxypregnenolone (17OHPREG) are two steroid precursors produced by the adrenal gland. The quantification of these compounds is essential for the evaluation of 3-β-hidroxidesidrogenase enzyme activity, which promotes the conversion of PREG in 17OHPREG. The 3-β:-hidroxidesidrogenase deficiency is a rare but severe type of adrenal hyperplasia that causes serious defects in steroid synthesis. Chromatographic methods coupled to mass spectrometry overcame immunoassays limitations such as reduced specificity, and have been widely used for steroids quantification. Recent years have been marked by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) hegemony due to the speed and possibility to analyze directly several analytes. However, in the case of type 3-hydroxy-5-ene steroids, which have low affinity for protons and, therefore, low ionization efficiency, many steps are required for conversion to detectable products. Notwithstanding, gas chromatography coupled to mass spectrometry (GC-MS) has some favorable features for steroid analysis such as unbeatable chromatographic efficiency. In addition, the incorporation of tandem mass spectrometry (GC-MS/MS) makes it as selective as LC-MS/MS. In this study, a new method for simultaneous extraction and derivatization of PREG and 17OHPREG from serum was developed. This procedure makes sample preparation for GC-MS/MS as simples as those described for LC-MS/MS. The detection method based on negative mode chemical ionization achieved the sensitivity required for the diagnosis of 3-β-hidroxidesidrogenase defficiency using only 250 µL of sample.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-05-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.