• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.10.2013.tde-04082014-133218
Documento
Autor
Nombre completo
Tatiana Paula Alvarenga de Carvalho Kamakura
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Ambrósio, Aline Magalhães (Presidente)
Fantoni, Denise Tabacchi
Otsuki, Denise Aya
Título en portugués
Avaliação da ventilação mecânica controlada a pressão utilizando-se a técnica de tomografia por impedância elétrica durante anestesia geral em cães
Palabras clave en portugués
Anestesia
Cão
Impedância
Recrutamento
Tomografia
Resumen en portugués
A hipoventilação secundária ao procedimento anestésico é comum na prática anestésica, e, sendo assim, o emprego de técnicas de ventilação mecânica é adotado como forma de minimizar e/ou evitar os efeitos deletérios da hipoventilação. Porém, o uso de ventiladores mecânicos não é isento de risco, e atelectasias podem se formar mesmo quando são utilizados. Para análise em tempo real do pulmão, a técnica de tomografia por impedância elétrica vem sendo empregada em conjunto com outros meios de monitoração, tendo se demonstrado um meio útil de avaliação da ventilação pulmonar de maneira não invasiva, passível de ser utilizada à beira do leito e sem emissão de radiação. Estudos utilizando o tomógrafo de impedância elétrica em cães são escassos. O objetivo desse trabalho foi avaliar a ventilação de cães submetidos à anestesia inalatória e à ventilação mecânica utilizando a técnica de tomografia por impedância elétrica. Foram utilizados onze cães com peso superior a 16 kg e classificados como baixo risco anestésico (ASA I ou II). Os animais receberam acepromazina e meperidina como medicação pré-anestésica, propofol como indutor e isofluorano na manutenção da anestesia. Foram mantidos em ventilação mecânica controlada a pressão, com FiO2 de 0,6 e pressão de pico de 10 cmH2O durante os primeiros 90 minutos de anestesia. Foram então realizadas manobras de recrutamento alveolar e instituição de pressão positiva ao final da expiração (PEEP) de 5 cmH2O, e os animais foram avaliados por mais 35 minutos. Os parâmetros foram avaliados 30, 60 e 90 minutos após a indução da anestesia e 5 e 35 minutos após o recrutamento e instituição da PEEP. Apesar de não ter havido diferença estatisticamente significativa nos parâmetros de oxigenação e distribuição da ventilação, foi visível a melhora clínica e nas curvas de oxigenação e impedância. As curvas de impedância geradas a partir dos dados obtidos pelo tomógrafo de impedância elétrica acompanharam as curvas de melhora na oxigenação. O fato de, no estudo, terem sido utilizados animais hígidos e submetidos à ventilação mecânica e FiO2 de 0,6 desde o início pode ter contribuído para não ter havido melhora estatisticamente significativa, embora clinicamente visível. As manobras de recrutamento utilizadas também foram conservadoras em comparação aos outros trabalhos realizados. Infere-se que, se utilizássemos animais doentes e com FiO2 de 1, poderíamos ter obtido um grau maior de atelectasias nos primeiros 90 minutos de anestesia e/ou, se tivéssemos utilizado manobras de recrutamento menos conservadoras, poderíamos ter obtidos melhora estatisticamente significativa após as manobras e instituição da PEEP. A tomografia de impedância elétrica parece ser um bom meio de monitoração do pulmão em tempo real em cães submetidos à anestesia inalatória.
Título en inglés
Evaluation of pressure-controlled ventilation using the technique of electrical impedance tomography during general anesthesia in dogs
Palabras clave en inglés
Anesthesia
Dog
Impedance
Recruitment
Tomograhy
Resumen en inglés
Hypoventilation secondary to anesthesia is common and, therefore, the use of mechanical ventilation techniques is adopted in order to minimize and/or prevent the deleterious effects of hypoventilation. However, the use of mechanical ventilators has risks, and atelectasis can develop even when they are used. For real-time analysis of the lung, the technique of electrical impedance tomography has been used in conjunction with other means of monitoring, having demonstrated to be useful for assessing pulmonary ventilation in a noninvasively way, and also can be used at the bedside and without radiation emission. There are not many studies using electrical impedance tomography in dogs. The aim of this study was to evaluate the ventilation of dogs subjected to inhalation anesthesia and mechanical ventilation using the technique of electrical impedance tomography. We used eleven dogs weighing more than 16 kg and classified as low anesthetic risk (ASA I or II). The animals were premedicated with acepromazine and meperidine, anesthesia was induced with propofol and maintained with isoflurane. Ventilation was then instituted with FiO2 of 0.6 and peak pressure of 10 cm H2O during the first 90 minutes of anesthesia. Alveolar recruitment maneuvers were realized and pressure positive end- expiratory pressure (PEEP) of 5 cmH2O was initiated. The animals were evaluated for more 35 minutes then. The parameters were measured at 30, 60 and 90 minutes after induction of anesthesia and 5 and 35 minutes after recruitment. Although there was no statistically significant difference in the parameters of oxygenation and ventilation distribution, clinical improvement was visible as was the oxygenation and impedance curves. The impedance curves generated from the data obtained with the electrical impedance tomograph followed the improvement in oxygenation curves. The fact that in this study we used healthy animals undergoing mechanical ventilation with FiO2 of 0.6 right from the beginning, may have contributed to no improvement statistically significant but clinically visible. Recruitment maneuvers used were also conservative in comparison to other papers. We think that, if we used animals and patients with FiO2 of 1, we could have obtained a higher degree of atelectasis in the first 90 minutes of anesthesia and/or, if we had used less conservative recruitment maneuvers, we could have obtained statistically significant improvement after maneuvers and institution of PEEP. The electrical impedance tomography seems to be a good means of real time monitoring the lung of dogs undergoing inhalation anesthesia.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-09-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.