• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.10.2016.tde-04122013-110723
Documento
Autor
Nombre completo
Lilian Sayuri Tatibana Fujimura
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Fantoni, Denise Tabacchi (Presidente)
Ambrósio, Aline Magalhães
Pereira, Patricia Mendes
Título en portugués
Avaliação da qualidade in vitro do concentrado de hemácias felino colhido e armazenado em sistema manufaturado
Palabras clave en portugués
Concentrado de hemácias felino
Gato
Transfusão
Resumen en portugués
Esse estudo teve por objetivo avaliar a viabilidade e qualidade in vitro do concentrado de hemácias felino (CHF), colhido e armazenado em bolsas e produtos nacionais, remanufaturadas, pelo Laboratório de Hemoterapia do Serviço de Anestesia da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo, de acordo com normas definidas por órgãos regulamentadores como a ANVISA. Foram analisados parâmetros bioquímicos e hematológicos de 24 unidades de CHF nos dias 0, 14 e 21 de armazenamento. Utilizou-se sistema fechado para colheita e armazenamento do sangue com solução de anticoagulante-preservativa CPDA-1. A avaliação consistiu na mensuração de porcentagem de hematócrito, hemoglobina total, hemoglobina extracelular, porcentagem de hemólise, concentrações de potássio, lactato, glicose, ATP, pH, bicarbonato, pressão de CO2 e O2, inspeção visual da bolsa e cultura microbiológica aeróbia e anaeróbia. Os resultados obtidos foram avaliados estatisticamente por meio de testes paramétricos, sendo que as determinações de hematócrito, hemoglobina total não apresentaram variação significante nos 21 dias de preservação, enquanto os de potássio, lactato, pO2 aumentaram gradativamente de forma significante. Os níveis de ATP, glicose, pH, bicarbonato e pCO2 reduziram de forma significante com o decorrer do tempo. Não houve alteração à inspeção visual das bolsas de sangue, nem crescimento de microorganismos nas culturas realizadas. Por meio destas avaliações constatouse que o sistema remanufaturado com produtos nacionais pode ser empregado com segurança para obtenção de sangue felino tendo-se em vista que se manteve estéril, com eficiente conservação do concentrado de hemácias felino em CPDA-1 até o 21º dia de armazenamento.
Título en inglés
Evaluation of the in vitro quality of the feline packed red blood cells collected and stored in manufactured system
Palabras clave en inglés
Cat
Feline packed red blood cells
Transfusion
Resumen en inglés
This study aimed to evaluate the feasibility and quality of in vitro feline packed red blood cells (CHF), harvested and stored in bags and domestic products, manufactured, Hematology Laboratory at the Department of Anesthesia, Faculty of Veterinary Medicine, University of São Paulo, according to standards set by regulatory bodies such as ANVISA. Were analyzed biochemical and hematological parameters 24 units of CHF on days 0, 14 and 21 of storage. We used a closed system for collection and storage of blood with preservative-anticoagulant solution CPDA-1. The evaluation consisted in measuring percentage of hematocrit, total hemoglobin, extracellular hemoglobin, percentage of hemolysis, potassium concentrations, lactate, glucose, ATP, pH, bicarbonate, CO2 and O2 pressure, visual inspection of the bag and aerobic and anaerobic microbiological culture . The results were statistically analyzed using parametric tests, and determinations of hematocrit, total hemoglobin showed no significant variation within 21 days of preservation, while potassium lactate, pO2 gradually increased significantly. ATP levels, glucose, pH, pCO2 and bicarbonate decreased significantly with time. There was no change to the visual inspection of blood bags, or growth of microorganisms in the cultures performed. Through these evaluations it was found that the system refilled with domestic products can be used safely for obtaining blood feline bearing in mind that remained sterile, efficient storage of red blood cells feline in CPDA-1 until the 21 th days of storage.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-12-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.