• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.10.2019.tde-11062019-143548
Documento
Autor
Nombre completo
Felipe Silveira Rêgo Monteiro de Andrade
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2018
Director
Tribunal
Ambrósio, Aline Magalhães (Presidente)
Fantoni, Denise Tabacchi
Martins, Alessandro Rodrigues de Carvalho
Mott, Lara Lopes Facó
Otsuki, Denise Aya
Título en portugués
Avaliação da manobra de recrutamento alveolar por titulação da PEEP por meio da técnica de tomografia por impedância elétrica em equinos submetidos à anestesia geral inalatória
Palabras clave en portugués
Equino
Manobra de recrutamento alveolar
Mecânica ventilatória
Tomografia por impedância elétrica
Resumen en portugués
A principal causa da disfunção respiratória em equinos durante anestesia geral inalatória é atribuída à hipoxemia devido a formação de áreas de atelectasias. Visando reverter estes quadros são instituídas as manobras de recrutamento alveolar (MRA) através da administração de elevadas pressões no sistema respiratório. Estas manobras quando utilizadas de maneira inadequada podem contribuir para a formação de atelectasias, barotrauma, volutrauma e até mesmo atelectrauma; sendo de suma importância a sua monitoração. Com isso, uma nova técnica, a tomografia por impedância elétrica (TIE), vem sendo estudada, no qual, seu funcionamento se dá por emissão de corrente elétrica de baixa frequência e intensidade nos tecidos, gerando uma imagem dos tecidos avaliados. Sendo assim, o objetivo do presente estudo experimental foi avaliar se na espécie equina a TIE é capaz de visualizar as alterações de volume corrente global e regional, em pulmões saudáveis, durante a ventilação mecânica e escalonamento da PEEP como MRA. Para tanto foram utilizados 14 equinos de peso médio de 306 kg, submetidos a anestesia geral inalatória em decúbito dorsal. Os animais foram mecanicamente ventilados com volume corrente de 14 mL/kg e frequência respiratória de 7-9 mpm. Foi instituída manobra de recrutamento alveolar, aumentando-se a PEEP de 5 em 5 cmH2O, a cada 5 minutos, até 32 cmH2O, seguido de seu decréscimo também de 5 em 5 cmH2O, a cada 5 minutos, até 7 cmH2O. Foram realizadas coletadas de amostras de sangue arterial para hemogasometria, imagens do TIE e registrados os parâmetros hemodinâmicos e de mecânica respiratória em cada estágio do escalonamento da PEEP. Durante a MRA foram observados aumento na PaO2/FiO2 dos pacientes assim como aumento na complacência estática pulmonar, associado a uma diminuição no shunt pulmonar, e deslocamento da ventilação para região pulmonar dependente por meio da TIE, principalmente em PEEP acima de 17 cmH2O. Como efeitos adversos foram observados alterações em parâmetros hemodinâmicos sendo estas transitórias. Portanto o TIE demonstrou-se capaz de avaliar as mudanças de ventilação pulmonar durante a MRA e mostrou relação com os ganhos em oxigenação e mecânica pulmonar.
Título en inglés
Evaluation of recruitment manoeuvre by PEEP titration assessed by electrical impedance tomography in horses undergoing isoflurane anaesthesia
Palabras clave en inglés
Alveolar recruitment manoeuvre
Electrical impedance tomography
Equine
Ventilatory mechanics
Resumen en inglés
The main cause of respiratory dysfunction in horses under isoflurane anaesthesia is hypoxemia attributed to the atelectasis formation areas. In order to revert these sets, alveolar recruitment manoeuvres (ARM) are instituted through high pressures administration in the respiratory system. These manoeuvres when used improperly can contribute to the atelectasis formation, barotrauma, volutrauma and even atelectrauma; being of utmost importance its monitoring. A new technique, electrical impedance tomography (EIT), has been studied, in which its operation is due to the low frequency and intensity of electric current emission in the tissues, generating tissues images for evaluation. Therefore, the present experimental study aimed to evaluate whether in horses the EIT is able to visualize changes of global and regional tidal volume in healthy lungs during mechanical ventilation and titration of PEEP as ARM. For this purpose, 14 horses weighting 306 kg were used, undergoing general inhalation anaesthesia in dorsal recumbence. The animals were mechanically ventilated with tidal volume of 14 mL/kg and respiration rate of 7-9 bpm. An alveolar recruitment manoeuvre was instituted, increasing the PEEP by 5 cmH2O every 5 minutes until 32 cmH2O, followed by decreasing it by 5 cmH2O every 5 minutes to 7 cmH2O. Arterial blood samples were collected for hemogasometry, EIT images and hemodynamic parameters and respiratory mechanics were recorded at each stage of PEEP. During ARM, patients' PaO2/FiO2 increased as well as increased pulmonary static compliance, associated with a decrease in pulmonary shunt, and pulmonary ventilation moving to dependent areas, mainly when 17 cmH2O or more were applied. As adverse effects were observed transient changes in hemodynamic parameters. So TIE is capable of presenting the changes in pulmonary ventilation in horse in dorsal recumbency undergoing ARM, and showed good relation to oxygenation gain and respiratory mechanics.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-07-17
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.