• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.10.2012.tde-11102012-091802
Documento
Autor
Nome completo
Gabriela Paola Ribeiro Banon
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2012
Orientador
Banca examinadora
Pinto, Ana Carolina Brandão de Campos Fonseca (Presidente)
Lorigados, Carla Aparecida Batista
Martin, Benedicto Wlademir de
Mascarenhas, Nelson Delfino d'Ávila
Muramoto, Caterina
Título em português
Mensurações radiográficas computadorizadas da silhueta cardíaca em cães da raça Poodle portadores de insuficiência valvar mitral
Palavras-chave em português
Cães
Coração
Medidas
Processamento de imagem
Radiografia
Resumo em português
Avaliaram-se os métodos de mensuração radiográficos, Vertebral Heart Size (VHS), o ângulo entre o eixo maior do coração e o esterno (ângulo) e a área cardíaca normalizada (ACN), na triagem Poodles portadores de insuficiência valvar mitral (IVM). Alocou-se um conjunto de 74 imagens radiográficas do tórax de Poodles em dois grupos: (I) estruturas cardiopulmonares normais (n = 18) e (II) portadores de doença cardíaca (n = 56), confirmada pelo ecocardiograma como sendo IVM. De acordo com a classificação do eco, o grupo II foi subdividido em quatro subgrupos: aumento atrial esquerdo (AAE) (IIa) leve (n = 4), (IIb) moderado (n = 7), (IIc) importante (n = 28) e (IId) ausente (n = 17). As mensurações foram realizadas na projeção laterolateral direita por um radiologista veterinário experiente (A) e por um iniciante (B). As mensurações de A foram consideradas referência. Para o VHS, houve diferenças significativas entre o grupo I e os grupos II (P < 0,001), IIb (P < 0,05) e IIc (P < 0,001). O limiar ótimo médio foi de 9,85v e a precisão média de 78,34%. Houve diferenças significativas nas mensurações entre A e B nos grupos I (P < 0,05) e II (P < 0,001). Para o ângulo, houve diferenças significativas entre o grupo I e os grupos II (P < 0,05) e IIc (P < 0,05). O limiar ótimo médio foi de 60,57º e a precisão média de 77,57%. Houve diferenças significativas nas mensurações entre A e B nos grupos I (P < 0,001) e II (P < 0,001). Para a ACN, houve diferenças significativas entre o grupo I e os grupos II (P < 0,001), IIb (P < 0,05), IIc (P < 0,001) e IId (P < 0,05). O limiar ótimo médio foi de 18,81v2 e a precisão média de 80.42%. Houve diferenças significativas nas mensurações entre A e B nos grupos I (P < 0,05) e II (P < 0,001). O desempenho do VHS na triagem de Poodles portadores de IVM foi regular. Identificou principalmente o aumento cardíaco generalizado. O desempenho do ângulo na triagem foi baixo. Reconheceu somente o aumento cardíaco generalizado. O desempenho da ACN na triagem foi bom. Identificou o AAE específico e alterações precoces na forma do coração. Para determinar o limiar ótimo, favoreceu-se a sensibilidade em detrimento da especificidade. A reprodutibilidade pareceu estar relacionada ao nível de experiência.
Título em inglês
Computed-aid radiographic measurements of cardiac silhouette in Poodle dogs with mitral valve insufficiency
Palavras-chave em inglês
Dogs
Heart
Image processing
Measures
Radiography
Resumo em inglês
Radiographic measurement methods, Vertebral Heart Size (VHS), angle between long axis of the heart and sternum (angle) and normalized cardiac area (NCA), were evaluated in clinical trials of Poodles with mitral valve insufficiency (MVI). Seventy four sets of thoracic radiographs of Poodles were allotted to two groups: (I) normal cardiopulmonary structures (n = 18) and (II) from patients with proven cardiac disease (n = 56), confirmed by echocardiography to be caused by MVI. According to ecocardiographic classification, group II was subdivided in four subgroups: (IIa) mild (n = 4), (IIb) moderate (n = 7), (IIc) severe (n = 28) and (IId) absent (n = 17) left atrial enlargement (LAE). Measurements were performed by one experienced veterinary radiologist (A) and one trainee (B) in right lateral view. The measurements of A were used as reference. For VHS, there were significant differences between group I and groups II (P < 0.001), IIb (P < 0.05) and IIc (P < 0.001). The optimal threshold value mean was 9.85v and the median accuracy of 78.34%. There were significant differences in the measurements between A and B in groups I (P < 0.05) and II (P < 0.001). For angle, there were significant differences between group I and groups II (P < 0.05) and IIc (P < 0.05). The optimal threshold value mean was 60.57º and the median accuracy of 77.57%. There were significant differences in the measurements between A and B in groups I (P < 0.001) and II (P < 0.001). For NCA, there were significant differences between group I and groups II (P < 0.001), IIb (P < 0.05), IIc (P < 0.001) and IId (P < 0.05). The optimal threshold value mean was 18.81v2 and the median accuracy of 80.42%. There were significant differences in the measurements between A and B in groups I (P < 0.05) and II (P < 0.001). The VHS´ performance in clinical trials of Poodles with MVI was regular. It mainly identified generalized cardiac enlargement. The angle´s performance in clinical trials was low. It only recognized generalized cardiac enlargement. The NCAs performance in clinical trials was good. It identified specific LAE and early changes in heart shape. To determine optimal threshold, sensitivity was prioritized, to the detriment of specificity. The reproducibility seemed to be related to the level of experience.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2013-05-02
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.