• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.10.2014.tde-11112014-150454
Documento
Autor
Nombre completo
Rodrigo Crispim Moreira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Zoppa, André Luis do Valle de (Presidente)
Corrêa, Rodrigo Romero
Foz Filho, Roberto Pimenta de Pádua
Schmaedecke, Alexandre
Silva, Luis Claudio Lopes Correia da
Título en portugués
Avaliação da resistência mecânica à compressão axial da poliuretana de mamona e quitosana associada a cimento de fosfato de cálcio no preenchimento de falhas ósseas do terceiro metacarpiano de equinos
Palabras clave en portugués
Biopolímeros
Ensaio biomecânico
Osso
Poliuretana de mamona
Quitosana
Resumen en portugués
Os equinos são animais que, quando adultos, apresentam elevado peso corpóreo e ossos bastante resistentes para sustentar esse peso. Dessa forma, para que ocorra fratura nos ossos do cavalo é necessário um trauma de elevada energia resultando em fraturas cominutivas, que podem formar falhas ósseas impedindo o contato entre os fragmentos ósseos, o que compromete a estabilidade e resistência da osteossíntese. Devido à complexidade desse tipo de fraturas e aos implantes disponíveis apresentarem baixa resistência para o uso nessa espécie e devido a seu comportamento, o tratamento de fraturas em equinos apresenta baixos índices de sucesso. Dessa maneira, o uso de um material osteocondutor com resistência mecânica para o preenchimento dessas falhas poderia elevar a resistência da osteossíntese, levando a melhores índices de sucesso na correção dessas fraturas. O presente estudo teve como objetivo a avaliação biomecânica em laboratório de dois biomateriais substitutos ósseos no preenchimento de falha óssea. Para isso foram utilizados 30 ossos terceiro metacarpiano de equinos que foram submetidos a osteossíntese com placa LCP em sua face dorsal e criada uma falha óssea transversal completa de um centímetro na diáfise média. Dez dessas peças foram submetidas a ensaios biomecânicos não destrutivos até a carga de 1000N, onde foram avaliadas a rigidez, as deformações da peça inteira, da placa e do osso individualmente em diferentes regiões. As outras 20 dessas peças foram submetidas a ensaios destrutivos, onde foram avaliadas a carga e deformação suportada no limite elástico e no ponto de ruptura. Dessa forma, pôde-se observar que houve aumento na rigidez de 699,39N/mm para 2905,38N/mm e 4274,93N/mm devido ao preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A peça inteira teve sua deformação diminuída de 1,73mm para 0,5mm e 0,35 com carga de 1000N, devido ao preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A placa teve sua deformação diminuída de 2260,64µd para 320,25µd pelo preenchimento da falha com poliuretana de mamona e para 89,88µd com o preenchimento com quitosana durante a aplicação de 1000N. O osso próximo à falha sofreu maiores deformações tanto com poliuretana de mamona quanto com quitosana, contudo não apresentou maiores deformações em região distante da falha. A peça inteira teve aumento da carga suportada em seu limite elástico de 1008N para 8804N apenas com o preenchimento da falha com quitosana. A peça inteira teve sua deformação diminuída de 1,64mm para 1,26 no limite elástico apenas devido ao preenchimento da falha poliuretana de mamona. A peça inteira teve aumento da força suportada no momento de ruptura de 1660N para 15187N e 11012N com o preenchimento da falha com poliuretana de mamona e quitosana, respectivamente. A peça inteira teve sua deformação máxima no ponto de ruptura diminuída de 5,4mm para 2,16mm apenas com o preenchimento da falha com quitosana.
Título en inglés
Mechanical evaluation of strength of ricinus communis polyurethane and chitosan with calcium phosphate cement on filling of bone gap in equine third metacarpal bone
Palabras clave en inglés
Biomechanical assay
Biopolymers
Bone
Chitosan
Ricinus communis polyurethane
Resumen en inglés
Adult horses are heavy animals equipped with bones strong enough to support their body weight. High energy trauma is required to produce comminuted fractures, where bone loss may prevent proper fracture reduction and compromise osteosynthesis resistance and stability. In horses, aside from behavioural issues, low success rates associated with comminuted fracture resolution may be due to the complexity of such fractures or the low resistance of bone implants. Therefore, osteoconductive biomaterials with good mechanical resistance would potentially benefit treatment outcomes. This ex vivo study evaluated the biomechanical behaviour of two bone surrogate biomaterials in experimental third metacarpal fractures in horses. Thirty equine third metacarpal bone specimens were submitted to dorsal LCP (locking compression plate) osteosynthesis following creation of a transverse 1 cm wide middiaphiseal defect. Defects were filled either with Ricinus communis polyurethane or calcium phosphate cement-chitosan composite. Ten specimens were submitted to non-destructive biomechanical testing under 1000N maximum load; construct stiffness, construct deformation and isolated deformation of LCP and third metacarpal bone in different regions were evaluated. The remaining 20 specimens were submitted to destructive biomechanical testing; maximum load and deformation within the elastic limit, and to failure were documented. Bone defect repair with RCP or CPC-chitosan composite increased construct stiffness from 699,39N/mm to 2905.38N/mm and 4274.93N/mm and decreased construct deformation under 1000N from 1.73mm to 0,5mm and 0.35 respectively. LCP deformation under 1000N decreased from 2260.64d to 320.25µd and from 2260.64µd to 89.88d following filling of the bone defect with RCP or CPC-chitosan composite respectively. Bone deformation around the defect increased following treatment with RCP or CPC-chitosan composite. However bone deformation away from the defect remained unchanged. Maximum load within the elastic limit increased from 1008N to 8804N when the experimental defect was filled with chitosan composite. Conversely, construct deformation within the elastic limit decreased from 1.64mm to 1.26mm following treatment with RCP. Maximum load to construct failure increased from 1660N to 15187N and 11012N following bone defect repair with RCP or calcium phosphate cement-chitosan composite respectively. However, construct maximum deformation decreased from 5.4mm to 2.16mm when calcium phosphate cement-chitosan composite was used.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.