Master's Dissertation
DOI
https://doi.org/10.11606/D.10.2008.tde-23042009-095807
Document
Author
Full name
Marcos Ishimoto Della Nina
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2008
Supervisor
Committee
Ferrigno, Cássio Ricardo Auada (President)
Garcia Filho, Reynaldo Jesus
Zoppa, André Luis do Valle de
Title in Portuguese
Estudo biomecânico do comportamento de diferentes espessuras de capa de cimento ósseo em novo modelo de prótese modular diafisária femoral em cão submetidas a ensaio de torção
Keywords in Portuguese
Biomecânica
Cães
Fêmur
Prótese
Torção
Abstract in Portuguese
A viabilidade da utilização de próteses modulares cimentadas em diáfises de fêmur em cães foi demonstrada, porém diversos autores relatam a falha de aderência entre as próteses e os ossos como uma das principais complicações. O presente trabalho teve como objetivo investigar biomecanicamente a interface implante metálico, osso e capa de cimento ósseo de com diferentes espessuras de cimento ósseo utilizadas para a estabilização da prótese. Para tanto foram utilizados fêmures bilaterais de 24 cadáveres de cães com peso acima de 15 quilos que foram divididos em quatro grupos, o primeiro grupo composto por oito fêmures utilizou uma espessura de capa de cimento de 1,0 a 1,5 mm, o segundo grupo, composto por oito fêmures, utilizou uma capa de cimento de 2,0 a 2,5 mm e o terceiro grupo, composto por oito fêmures, utilizou uma capa de cimento compreendida entre o intervalo de 3,0 a 3,5 mm de espessura. Os fêmures foram submetidos a ensaios destrutivos de torção onde foram avaliados a rigidez à torção e torque máximo suportado pela interface implante metálico, osso e capa de cimento ósseo. O quarto grupo, denominado de controle, composto pelos fêmures contralaterais íntegros, foram submetidos ao mesmo ensaio de torção que as peças onde foram utilizadas as próteses. Os resultados encontrados foram que nas condições apresentadas neste estudo não foi encontrada diferença biomecânica estatisticamente significante, em relação à rigidez à torção e torque máximo, na utilização de capas de cimento na faixa de 1 mm e 2,5 mm e entre 2 mm e 3,5 mm. Porém houve diferença quando comparado as faixas de espessura de cimento entre os grupos de 1 mm a 1,5mm e de 3 mm a 3,5 mm.
Title in English
Biomechanical analysis in the use of different cement layers in a new model of modular diaphyseal femoral implant relative to torsion forces
Keywords in English
Biomechanics
Dogs
Fêmur
Prosthesis
Torsion
Abstract in English
The feasibility of modular cemented prosthesis in the femoral diaphysis was demonstrated in dogs, but several authors report loosening of bone, cement and implant interface as a major complication. The objective of this study was to evaluate the stabilization of the prosthesis using different thicknesses of cement layer. For this study 48 femurs from 24 dogs weighing over 15 kilograms were used. They were separated in four groups, the first group with eight femurs used a cement mantle from 1.0 to 1.5 mm, the second group, with eight femurs, used a cement mantle from 2.0 to 2.5 mm and the third group, with eight femurs, used a cement layer from 3.0 to 3.5 mm. The femurs were submitted to destructive torsion tests where they were evaluated due to the values of torsional rigidity and maximum torque shown by the implant, bone and bone cement interface. In the fourth group were the remaining intact femurs, they were evaluated using the same torsion test used on the other groups. The results were that under the present conditions we found no biomechanical differences relative to torsional rigidity and maximum torque, using cement layers between 1 mm and 2.5 mm and between 2 mm and 3.5 mm. But we found biomechanical differences between groups of 1 mm to 1.5 mm and 3 mm to 3.5 mm.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-06-25
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • NINA, M. I. D., et al. estudo biomecanico do comprotamento de diferentes espessuras de capa de cimento ósseo em novo modelo de protese modular diafisária femoral em cão submetidos a ensaio de torção. Acta Scientiae Veterinariae , 2013, vol. 41, p. 1.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.