• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.10.2017.tde-27072017-155416
Document
Auteur
Nom complet
Thales Bregadioli
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Ferrigno, Cassio Ricardo Auada (Président)
Belangero, William Dias
Souza, Alexandre Navarro Alves de
Titre en portugais
Comparação biomecânica e da redução óssea do Clamp and Rod Internal Fixation e placa de reconstrução bloqueada em fraturas de acetábulo
Mots-clés en portugais
Bioengenharia
Cães
Cartilagem articular
Consolidação da Fratura
Fixação interna de fraturas
Resumé en portugais
Este estudo objetivou comparar, biomecanicamente, por meio dos ensaios de flexão destrutível e ciclagem, bem como a qualidade da redução óssea, após avaliação do molde da superfície articular de osteotomias centrais do acetábulo de cão fixadas com Clamp and Rod Internal Fixation (CRIF) 2,7 mm ou placa de reconstrução bloqueada 2,7 mm. Os implantes foram divididos em dois grupos, denominados grupo CRIF (GC) e grupo Placa (GP). Foram utilizadas nove pelves de cadáveres de cão com peso corporal entre 15 e 35 kg, posteriormente as pelves foram subdivididas em 18 hemipelves e distribuídas aleatoriamente para testar os dois implantes, um contralateral ao outro em uma mesma pelve. Para realização dos testes, foi simulado uma fratura central no acetábulo, por meio de osteotomia linear, realizada com auxílio de serra oscilatória e em seguida, fixadas segundo os padrões AO/SIF, sendo utilizados três parafusos craniais e dois caudais a osteotomia. Após comparação biomecânica de resistência máxima à flexão o GP (22,38±8,44 N.m) demonstrou superioridade estatística em relação ao GC (15,60±5,76 N.m), (p=0,02408). Na comparação do molde da superfície articular após 30 ciclos o GP (0,27 ± 0,24mm) demonstrou valores menores para lacuna da linha articular que o GC (0,49 ± 0,29mm), sendo o GP estatisticamente superior, (p=0,04784). Em conclusão, a aplicação da placa de reconstrução bloqueada é simples e deve ser considerada para redução de fraturas do acetábulo que necessitem de reconstrução anatômica.
Titre en anglais
Comparação biomecânica e da redução óssea de Clamp and Rod Internal Fixation (CRIF) e placa de reconstrução bloqueada em fraturas de acetábulo
Mots-clés en anglais
Bioengineering
Cartilage Articular
Dogs
Fracture Fixation Internal
Fracture Healing
Resumé en anglais
The aim of this study was to compare the accuracy of reduction and biomechanical characteristics of acetabular osteotomies repaired with 2.7-mm Clamp and Rod Internal Fixation (CRIF) constructs or 2.7-mm locking reconstruction plates in cyclic and load to failure flexion tests. Nine dog cadavers with body weight between 15 and 35 kg were included in this study. All 18 hemipelves were randomly assigned into two groups named after the implants tested, group CRIF (GC) and group Plate (GP). All pelves were used to test both groups with each hemipelvis belonging to a different implant group. Acetabular osteotomies were created with an oscillatory saw and then fixed according to the AO/ASIF standards, using either 5-hole, 2.7-mm locking reconstruction plates with three locked screws cranial and two caudal to the osteotomy line, or CRIF constructs with 5 clamps, three located cranial and two caudal to the osteotomy line. Load to failure at GP (22.38 ± 8.44N.m) was significantly higher than GC (15.60 ± 5.76N.m), (p = 0.02408). Imprinted cast of acetabular reduction gap after 30 cycles was statistically smaller at GP (0.27 ± 0.24mm) than GC (0.49 ± 0.29mm) (p = 0.04784). We concluded that the appliance of locking reconstruction plates is simple and should be considered for acetabular fractures, that require perfect anatomical reconstruction.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-08-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.