• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.102.2017.tde-23012017-112928
Document
Auteur
Nom complet
Caroline Antonelli Santesso
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2017
Directeur
Jury
Chvatal, Karin Maria Soares (Président)
Dornelles, Kelen Almeida
Lukiantchuki, Marieli Azoia
Neves, Leticia de Oliveira
Titre en portugais
Integração da ventilação híbrida e da iluminação natural em saletas comerciais na cidade de São Paulo: influência de parâmetros de projeto
Mots-clés en portugais
Eficiência energética
Iluminação natural
Percentual de área de abertura na fachada (PAF)
Simulação computacional
Ventilação híbrida
Resumé en portugais
Atualmente, os edifícios selados hermeticamente e com as chamadas "peles de vidro" estão presentes em diversos países, e possuem, como consequência, um elevado consumo de energia elétrica para conseguir manter o conforto ambiental dos usuários. Contudo, é possível se beneficiar de uma maior eficiência energética nesses espaços através da combinação de soluções ativas e passivas. Esse estudo tem como objetivo principal avaliar a influência de parâmetros de projetos, tais como o formato da sala, tamanho e orientação das aberturas na fachada, no consumo de energia e no conforto visual em saletas comerciais com ventilação híbrida e integração da iluminação natural com a artificial na cidade de São Paulo. As saletas comerciais analisadas possuem uma área média, diferentes formatos e diferentes aberturas em uma só fachada, representando a solução arquitetônica mais comum encontrada nesse tipo de edifício. Através de análise energética realizada por meio do programa EnergyPlus e da análise lumínica com o programa DIVA-for-Rhino, verificou-se que o formato da sala é essencial para a decisão de um percentual de área de abertura na fachada (PAF) que consuma menos energia. Os resultados mostraram que o uso da ventilação híbrida sempre representou uma economia, atingindo uma redução de até 51% do consumo do ar condicionado para resfriamento e até 26% do consumo de energia total, com os PAF´s de 40, 70 e 100%. Seria interessante considerar elementos de proteção solar que não diminuam a eficácia da ventilação e iluminação naturais nesses ambientes, para se aliar o baixo consumo de energia com menores riscos de ofuscamento. Desta forma, o trabalho auxilia a incorporação destas estrategias para uma maior economia de energia no desenvolvimento do projeto arquitetônico desta tipologia de edifício comercial.
Titre en anglais
Daylighting and hybrid ventilation integration in cellular offices in the city of São Paulo: design parameters influence.
Mots-clés en anglais
Computer simulation
Daylighting
Energy efficiency
Hybrid ventilation
Window-to-wall-ratio (WWR)
Resumé en anglais
Nowadays, sealed airtight office buildings and so-called "glass curtain wall" are present in many countries, and have as a result a high consumption of electric energy to be able to maintain the environmental comfort of the users. However, the combination of passive and active strategies could improve the energy efficiency in these spaces. This study aims to evaluate the design parameters influence, such as rooms shape, the openings size and orientation, in the energy consumption and in the visual comfort in cellular offices with hybrid ventilation system and the integration of daylight and artificial lighting in São Paulo. The analyzed cellular offices have an average area, different shapes and different openings in one facade, representing the more common architectural characteristics found in this type of building in that context. Energy analyses in EnergyPlus and daylight studies using DIVA-for-Rhino were conducted. It was found that the rooms shape is essential for the determination of the window-to-wall-ratio (WWR) for reducing energy consumption. The results showed that the hybrid ventilation use always represented an economy, reaching reduction values up to 51% in the consumption of air conditioning for cooling and up to 26% in cellular offices total consumption, with a WWR of 40, 70 and 100%. It would be interesting to consider sun shading elements that do not reduce the effectiveness of natural ventilation and daylighting in these environments to combine low power consumption with a lower risk of glare. In this way, the work helps the incorporation of these strategies for save energy in the development of the architectural design of this type of commercial building.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-01-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.