• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.11.1980.tde-20240301-150721
Documento
Autor
Nome completo
Rogério Remo Alfonsi
Unidade da USP
Data de Defesa
Imprenta
Piracicaba, 1979
Orientador
Título em português
Flutuação estacional da temperatura e da difusividade térmica para solo da região de Campinas, SP
Palavras-chave em português
DIFUSIDADE TÉRMICA
TEMPERATURA DO SOLO
Resumo em português
Foram estudadas as relações entre a temperatura do ar e do solo, bem como as variações sazonais da difusividade térmica, da profundidade de amortecimento, e da camada de extinção da onda de calor de um Latossolo roxo da região de Campinas-SP. Em geral, a temperatura média diária do solo pode selo estimada através de três observações feitas às 7, 14 e 21 horas locais, respectivamente. A análise de regressão linear mostrou haver boa associação entre as médias de temperatura do solo e do ar, tanto em escala mensal como anual. Para o período estudado (1967-1976) as diferenças entre as temperaturas do ar e do solo oscilaram entre 0,2 e 6,6 °C para a escala mensal, e foi praticamente constante e igual a 3, 2°C para a escala anual, sendo a temperatura do solo sempre maior que a temperatura do ar. Os valores diários da difusividade térmica do solo, da profundidade de amortecimento e da camada de extinção variariam entre 1,9x10-3 e 11,9x10 cm2/s, entre 5,3 e 18,0 cm, e entre 22,0 e 72,0 cm, respectivamente, para períodos chuvosos, enquanto que em sequências de dias sem chuva tais intervalos foram de 2,5x10-3 a 5,0x10-3cm2/s, 7,5 a 12,5 cm, e 40 a 60 cm, respectivamente.
Resumo em inglês
The relationships between air and soil temperatures as well as seasonal variations of termal diffusivity, damping depth, and extinction depth layer of the temperature wave, for a Latossolo roxo in the region of Campinas-SP were studied. In generial the mean daily temperature of the soil could well be estimated by three observation taken, respectively, at 7, 14, and 21 local hours. Linear regression analysis showed that therie exists a good association between the mean air and soil temperature in all time scales studied, i.e., month, and year. For the period used (1967-1976) the differences between air and soil temperatures were between 0,2 and 6,6°C in the month soale, and were constant and equal to 32° in the annual scale. The soil temperature was, always greater than the air temperatuve in all scales studied. Daily values of the thermal diffusivity, damping depth, and extinction depth layer for such soil were, respectively, between 1.9x10-3 and 1.1x10-3 cm-2/s, 5,3 and 18.0 cm, and 22.0 and 72.0 cm for rainy periods, while for dry spells the daily values were between 2. 5x10-3 and 5.0x10-3 cm2, 7.5 and 12.5 cm, and 40 and 60 cm respectively.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
708472.pdf (24.41 Mbytes)
Data de Publicação
2024-03-14
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.