• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.1980.tde-20240301-150721
Document
Auteur
Nom complet
Rogério Remo Alfonsi
Unité de l'USP
Date de Soutenance
Editeur
Piracicaba, 1979
Directeur
Titre en portugais
Flutuação estacional da temperatura e da difusividade térmica para solo da região de Campinas, SP
Mots-clés en portugais
DIFUSIDADE TÉRMICA
TEMPERATURA DO SOLO
Resumé en portugais
Foram estudadas as relações entre a temperatura do ar e do solo, bem como as variações sazonais da difusividade térmica, da profundidade de amortecimento, e da camada de extinção da onda de calor de um Latossolo roxo da região de Campinas-SP. Em geral, a temperatura média diária do solo pode selo estimada através de três observações feitas às 7, 14 e 21 horas locais, respectivamente. A análise de regressão linear mostrou haver boa associação entre as médias de temperatura do solo e do ar, tanto em escala mensal como anual. Para o período estudado (1967-1976) as diferenças entre as temperaturas do ar e do solo oscilaram entre 0,2 e 6,6 °C para a escala mensal, e foi praticamente constante e igual a 3, 2°C para a escala anual, sendo a temperatura do solo sempre maior que a temperatura do ar. Os valores diários da difusividade térmica do solo, da profundidade de amortecimento e da camada de extinção variariam entre 1,9x10-3 e 11,9x10 cm2/s, entre 5,3 e 18,0 cm, e entre 22,0 e 72,0 cm, respectivamente, para períodos chuvosos, enquanto que em sequências de dias sem chuva tais intervalos foram de 2,5x10-3 a 5,0x10-3cm2/s, 7,5 a 12,5 cm, e 40 a 60 cm, respectivamente.
Resumé en anglais
The relationships between air and soil temperatures as well as seasonal variations of termal diffusivity, damping depth, and extinction depth layer of the temperature wave, for a Latossolo roxo in the region of Campinas-SP were studied. In generial the mean daily temperature of the soil could well be estimated by three observation taken, respectively, at 7, 14, and 21 local hours. Linear regression analysis showed that therie exists a good association between the mean air and soil temperature in all time scales studied, i.e., month, and year. For the period used (1967-1976) the differences between air and soil temperatures were between 0,2 and 6,6°C in the month soale, and were constant and equal to 32° in the annual scale. The soil temperature was, always greater than the air temperatuve in all scales studied. Daily values of the thermal diffusivity, damping depth, and extinction depth layer for such soil were, respectively, between 1.9x10-3 and 1.1x10-3 cm-2/s, 5,3 and 18.0 cm, and 22.0 and 72.0 cm for rainy periods, while for dry spells the daily values were between 2. 5x10-3 and 5.0x10-3 cm2, 7.5 and 12.5 cm, and 40 and 60 cm respectively.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
708472.pdf (24.41 Mbytes)
Date de Publication
2024-03-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.