• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.11.1978.tde-20240301-154721
Documento
Autor
Nombre completo
Boaventura Freire dos Reis
Instituto/Escuela/Facultad
Fecha de Defensa
Publicación
Piracicaba, 1978
Director
Título en portugués
Determinação colorimétrica de alumínio em águas naturais, plantas e solos por injeção em fluxo contínuo
Palabras clave en portugués
ÁGUAS NATURAIS
ALUMÍNIO
ANÁLISE POR INJEÇÃO EM FLUXO CONTÍNUO
COLORIMETRIA
DETERMINAÇÃO
PLANTAS
SOLOS
Resumen en portugués
Desenvolveu-se um método para a determinação de alumínio em extratos de solos, material vegetal pré-digerido e em águas naturais empregando o reagente colorimétrico Eriocromo cianina R e a metodologia de injeção em fluxo contínuo. Estabeleceu-se o sistema de fluxo de modo a se conseguir uma taxa de determinações de 100 a 120 amostras por hora. O consumo de reagentes é otimizado, para a determinação de alumínio no intervalo de 0,25 a 10,00 ppm. Eliminou-se a interferência do íon férrico durante a residência da amostra no percurso analítico, mascarando-o com ácido ascórbico ou com ácido tioglicólico. Verificaram-se os níveis de interferências do fosfato e do fluoreto, e a partir de que concentrações as respectivas interferências são significativas. Os consumos de Eriocromo cianina R, ácido ascórbico o ácido tioglicólico e de acetato de amônia são respectivamente 6%, 11% e 13% em relação ao método manual. A média de recuperação pelo teste de adição controlada é de 96%, e a reprodutibilidade é da ordem de 1%.
Resumen en inglés
The colorimetric determination of aluminium in soil extracts, plant digests and natural waters with Eriocrom cyanin R was adapted to continuous flow-injection analysis. The proposed system presents a typical sampling rate of about 120 samples per hour, when the aluminium content is in the range between 0,25 and 10,00 ppm Good reproducibility and accuracy associated with low consumption of sample and reagent, which are characteristics of the flow-injection approach, were also attained. The iron (III) interference was studied and suppressed after sample injection, by using ascorbic acid or tioglicolic acid as masking agents. The phosphate and fluoride interferences in the Al-determination by the proposed method are discussed.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
724639.pdf (2.47 Mbytes)
Fecha de Publicación
2024-03-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.