Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.1978.tde-20240301-154721
Document
Auteur
Nom complet
Boaventura Freire dos Reis
Unité de l'USP
Date de Soutenance
Editeur
Piracicaba, 1978
Directeur
Titre en portugais
Determinação colorimétrica de alumínio em águas naturais, plantas e solos por injeção em fluxo contínuo
Mots-clés en portugais
ÁGUAS NATURAIS
ALUMÍNIO
ANÁLISE POR INJEÇÃO EM FLUXO CONTÍNUO
COLORIMETRIA
DETERMINAÇÃO
PLANTAS
SOLOS
Resumé en portugais
Desenvolveu-se um método para a determinação de alumínio em extratos de solos, material vegetal pré-digerido e em águas naturais empregando o reagente colorimétrico Eriocromo cianina R e a metodologia de injeção em fluxo contínuo. Estabeleceu-se o sistema de fluxo de modo a se conseguir uma taxa de determinações de 100 a 120 amostras por hora. O consumo de reagentes é otimizado, para a determinação de alumínio no intervalo de 0,25 a 10,00 ppm. Eliminou-se a interferência do íon férrico durante a residência da amostra no percurso analítico, mascarando-o com ácido ascórbico ou com ácido tioglicólico. Verificaram-se os níveis de interferências do fosfato e do fluoreto, e a partir de que concentrações as respectivas interferências são significativas. Os consumos de Eriocromo cianina R, ácido ascórbico o ácido tioglicólico e de acetato de amônia são respectivamente 6%, 11% e 13% em relação ao método manual. A média de recuperação pelo teste de adição controlada é de 96%, e a reprodutibilidade é da ordem de 1%.
Resumé en anglais
The colorimetric determination of aluminium in soil extracts, plant digests and natural waters with Eriocrom cyanin R was adapted to continuous flow-injection analysis. The proposed system presents a typical sampling rate of about 120 samples per hour, when the aluminium content is in the range between 0,25 and 10,00 ppm Good reproducibility and accuracy associated with low consumption of sample and reagent, which are characteristics of the flow-injection approach, were also attained. The iron (III) interference was studied and suppressed after sample injection, by using ascorbic acid or tioglicolic acid as masking agents. The phosphate and fluoride interferences in the Al-determination by the proposed method are discussed.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
724639.pdf (2.47 Mbytes)
Date de Publication
2024-03-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.