Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.1980.tde-20231122-100256
Document
Auteur
Nom complet
Dalva Martinelli Cury
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 1980
Directeur
Titre en portugais
Desenvolvimento de um "radiômetro de resistência elétrica" para medida de radiação solar global
Mots-clés en portugais
RADIAÇÃO SOLAR GLOBAL
RADIÔMETROS
RESISTÊNCIA ELÉTRICA
Resumé en portugais
O presente trabalho teve como objetivos a construção e ensaios preliminares de um radiômetro simples, que tem por elementos sensíveis, resistências de níquel de alto coeficiente térmico (high a,Nickel) dispostas em uma clássica ponte de Wheatstone. O sistema de detecção de sinal e realizado por um micro-amperímetro convencional. Foram construídos dois modelos de geometria de exposição diferentes denominados de RRE - 1 (radiômetro de resistência elétrica - 1) e RRE - 2 (radiômetro de resistência elétrica - 2). Nos testes realizados, os radiômetros RRE - 1 e RRE - 2 demonstraram resultados preliminares bastante razoáveis, sugerindo que tais modelos adaptados convenientemente , poderão ser úteis em estudos nos quais não é necessária uma altíssima precisão de medida (hidrologia, engenharia, ecologia, etc.). Os resultados dos testes do RRE - 1 foram os seguintes: (Descrito na Dissertação)
Titre en anglais
Not available
Resumé en anglais
The objective of the present work was the construction of and preliminary tests with a simple radiometer, the sensible elements of which are high a nickel resistances placed on a conventional Wheatstone's bridge. The system of signal detection is carried out by means of a conventional microam peremeter. Two geometrically different models were built, with different expositions, which were called RRE-1 (electric resistance radiometer - 1) and RRE-2 (electric resistance radiometer - 2) . The preliminary results obtained from tests carried out with radiometers RRE-1 and RRE-2 were quite reasonable suggesting that such models, when conveniently adapted, can be useful for studies for which highly accurate measurements are not required (hydrology, engineering, ecology, etc.). The results obtained from tests with the RRE-1 were the following: (See dissertation)
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-11-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.