• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.11.1980.tde-20231122-100256
Documento
Autor
Nombre completo
Dalva Martinelli Cury
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 1980
Director
Título en portugués
Desenvolvimento de um "radiômetro de resistência elétrica" para medida de radiação solar global
Palabras clave en portugués
RADIAÇÃO SOLAR GLOBAL
RADIÔMETROS
RESISTÊNCIA ELÉTRICA
Resumen en portugués
O presente trabalho teve como objetivos a construção e ensaios preliminares de um radiômetro simples, que tem por elementos sensíveis, resistências de níquel de alto coeficiente térmico (high a,Nickel) dispostas em uma clássica ponte de Wheatstone. O sistema de detecção de sinal e realizado por um micro-amperímetro convencional. Foram construídos dois modelos de geometria de exposição diferentes denominados de RRE - 1 (radiômetro de resistência elétrica - 1) e RRE - 2 (radiômetro de resistência elétrica - 2). Nos testes realizados, os radiômetros RRE - 1 e RRE - 2 demonstraram resultados preliminares bastante razoáveis, sugerindo que tais modelos adaptados convenientemente , poderão ser úteis em estudos nos quais não é necessária uma altíssima precisão de medida (hidrologia, engenharia, ecologia, etc.). Os resultados dos testes do RRE - 1 foram os seguintes: (Descrito na Dissertação)
Título en inglés
Not available
Resumen en inglés
The objective of the present work was the construction of and preliminary tests with a simple radiometer, the sensible elements of which are high a nickel resistances placed on a conventional Wheatstone's bridge. The system of signal detection is carried out by means of a conventional microam peremeter. Two geometrically different models were built, with different expositions, which were called RRE-1 (electric resistance radiometer - 1) and RRE-2 (electric resistance radiometer - 2) . The preliminary results obtained from tests carried out with radiometers RRE-1 and RRE-2 were quite reasonable suggesting that such models, when conveniently adapted, can be useful for studies for which highly accurate measurements are not required (hydrology, engineering, ecology, etc.). The results obtained from tests with the RRE-1 were the following: (See dissertation)
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-11-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.