A determinação de selênio por fluorimetria
Mots-clés en portugais
DETERMINAÇÃO
FLUOROMETRIA
SELÊNIO
Resumé en portugais
Foi desenvolvido um método fluorimétrico para a determinação de selênio em amostras vegetais e soro de sangue. O método empregou inicialmente o radioisótopo <sup>75</sup>Se para atingir as condições analíticas de determinação. Foram estudados três processos de digestão de amostras e alguns fatores relativos à metodologia. Com o processo de digestão nítrico-perclórica, cerca de 40 amostras podem ser analisadas diariamente com relativa facilidade. Foi adicionado HCl (1+9) ao digerido e submetido ao banho-maria a 90°C por 30 minutos. O procedimento analítico básico consistiu na reação do selênio com 2,3-diaminonaftaleno (DAN) 4 x 10<sup>-3</sup>M a pH 2 durante 60 minutos a 70°C e extração do complexo Se-DAN com ciclohexano. O método proposto apresentou um coeficiente de variação em torno de 9%, uma recuperação média superior a 90% e uma exatidão considerada excelente.
Titre en anglais
Selenium determination by fluorimetry
Resumé en anglais
A fluorimetric method was developed to determine selenium both in vegetal samples and blood serum. The method consists of a radioisotope <sup>75</sup>Se initially in order to optimize the determination of analytical conditions. Three samples digestion processes were studied and also some factors related to methodology. Thanks to the nitric-percloric digestion process, around 40 samples can be analyzed daily in a relatively easy way. HCl (1+9) was added to the digested material and submitted to water-bath at 90°C during 30 minutes. The basic analytical process consisted of the selenium reaction with 2,3- diaminonaphthalene (DAN) 4 x 10<sup>-3</sup>M at 2 pH during 60 minutes at 70°C and extraction of Se-DAN complex with cyclohexane. The proposed method showed a coefficient of variation of about 9%, an average recovery superior to 90% and excellent accuracy.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2021-09-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.