Disertación de Maestría
DOI
https://doi.org/10.11606/D.11.1981.tde-20220207-164109
Documento
Autor
Nombre completo
Orghêda Luiza Araujo Domingues Zucchi
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 1981
Director
Título en portugués
Equipamentos nucleares na determinação dos coeficientes de atenuação de massa de solos e da água
Palabras clave en portugués
ÁGUA DO SOLO
COEFICIENTES DE ATENUAÇÃO DE MASSA
EQUIPAMENTOS NUCLEARES
Resumen en portugués
Com o intuito de se difundir e facilitar o uso da técnica de atenuação da radiação gama, foi desenvolvido um estudo para se determinar a viabilidade de substituição do espectrômetro gama monocanal, tradicionalmente usado nesta técnica, por um sistema de contagem integral de custo mais baixo, capaz de ser operado por pessoal com menor especialização. Fez-se um estudo da determinação dos coeficientes de atenuação de massa para vários tipos de solo e para agua, empregando-se três sistemas de detecção: (1) espectrômetro gama monocanal, operando em contagem no fotopico (0,66 ± 0,07 MeV); (2) operando em contagem integral (0,1 a 1,0 MeV) e (3) um scaler conectado diretamente a fotomultiplicadora. Também foi levado em consideração a eliminação dos raios-X de 32 keV proveniente do Ba-137m, raios gama retroespalhados na blindagem e na fonte e a correção do tempo morto. Concluiu-se que a substituição do espectrômetro gama monocanal pelo scaler é perfeitamente viável.
Título en inglés
Nuclear equipment to determine soil and water mass attenuation coefficients
Resumen en inglés
A study was carried out to determine the feasibility of substituting the monochannel gamma spectrometer, traditionally used in the gamm ray attenuation technique, for a less sophisticated and less expensive system of integral counting, which could be operated by a non-special ized person. This was done to make this technique better known·and used. Three detection systems were used in the determination of the mass attenuation coefficients for different types of soil and for water: (1) monochannel gamma spectrometer, operating at photopeak counting (0.66 ± 0.07 MeV) (2) operating at integral counting (0.1 - 1.0 MeV), and (3) a scaler directly connected to the photomultiplier. Also taken into consideration were: the elimination of X-rays of 32 keV from the Ba-137m, gamma-rays back-scattering in the shield and in the source, and correction of dead time. After analysis of the results we came to the conclusion that it is perfectly feasible to substitute the monochannel gamma spectrometer for the system using a scaler.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-02-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.