• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.11.1981.tde-20220207-164109
Documento
Autor
Nome completo
Orghêda Luiza Araujo Domingues Zucchi
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Piracicaba, 1981
Orientador
Título em português
Equipamentos nucleares na determinação dos coeficientes de atenuação de massa de solos e da água
Palavras-chave em português
ÁGUA DO SOLO
COEFICIENTES DE ATENUAÇÃO DE MASSA
EQUIPAMENTOS NUCLEARES
Resumo em português
Com o intuito de se difundir e facilitar o uso da técnica de atenuação da radiação gama, foi desenvolvido um estudo para se determinar a viabilidade de substituição do espectrômetro gama monocanal, tradicionalmente usado nesta técnica, por um sistema de contagem integral de custo mais baixo, capaz de ser operado por pessoal com menor especialização. Fez-se um estudo da determinação dos coeficientes de atenuação de massa para vários tipos de solo e para agua, empregando-se três sistemas de detecção: (1) espectrômetro gama monocanal, operando em contagem no fotopico (0,66 ± 0,07 MeV); (2) operando em contagem integral (0,1 a 1,0 MeV) e (3) um scaler conectado diretamente a fotomultiplicadora. Também foi levado em consideração a eliminação dos raios-X de 32 keV proveniente do Ba-137m, raios gama retroespalhados na blindagem e na fonte e a correção do tempo morto. Concluiu-se que a substituição do espectrômetro gama monocanal pelo scaler é perfeitamente viável.
Título em inglês
Nuclear equipment to determine soil and water mass attenuation coefficients
Resumo em inglês
A study was carried out to determine the feasibility of substituting the monochannel gamma spectrometer, traditionally used in the gamm ray attenuation technique, for a less sophisticated and less expensive system of integral counting, which could be operated by a non-special ized person. This was done to make this technique better known·and used. Three detection systems were used in the determination of the mass attenuation coefficients for different types of soil and for water: (1) monochannel gamma spectrometer, operating at photopeak counting (0.66 ± 0.07 MeV) (2) operating at integral counting (0.1 - 1.0 MeV), and (3) a scaler directly connected to the photomultiplier. Also taken into consideration were: the elimination of X-rays of 32 keV from the Ba-137m, gamma-rays back-scattering in the shield and in the source, and correction of dead time. After analysis of the results we came to the conclusion that it is perfectly feasible to substitute the monochannel gamma spectrometer for the system using a scaler.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2022-02-07
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.