• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.1981.tde-20220207-164109
Document
Auteur
Nom complet
Orghêda Luiza Araujo Domingues Zucchi
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 1981
Directeur
Titre en portugais
Equipamentos nucleares na determinação dos coeficientes de atenuação de massa de solos e da água
Mots-clés en portugais
ÁGUA DO SOLO
COEFICIENTES DE ATENUAÇÃO DE MASSA
EQUIPAMENTOS NUCLEARES
Resumé en portugais
Com o intuito de se difundir e facilitar o uso da técnica de atenuação da radiação gama, foi desenvolvido um estudo para se determinar a viabilidade de substituição do espectrômetro gama monocanal, tradicionalmente usado nesta técnica, por um sistema de contagem integral de custo mais baixo, capaz de ser operado por pessoal com menor especialização. Fez-se um estudo da determinação dos coeficientes de atenuação de massa para vários tipos de solo e para agua, empregando-se três sistemas de detecção: (1) espectrômetro gama monocanal, operando em contagem no fotopico (0,66 ± 0,07 MeV); (2) operando em contagem integral (0,1 a 1,0 MeV) e (3) um scaler conectado diretamente a fotomultiplicadora. Também foi levado em consideração a eliminação dos raios-X de 32 keV proveniente do Ba-137m, raios gama retroespalhados na blindagem e na fonte e a correção do tempo morto. Concluiu-se que a substituição do espectrômetro gama monocanal pelo scaler é perfeitamente viável.
Titre en anglais
Nuclear equipment to determine soil and water mass attenuation coefficients
Resumé en anglais
A study was carried out to determine the feasibility of substituting the monochannel gamma spectrometer, traditionally used in the gamm ray attenuation technique, for a less sophisticated and less expensive system of integral counting, which could be operated by a non-special ized person. This was done to make this technique better known·and used. Three detection systems were used in the determination of the mass attenuation coefficients for different types of soil and for water: (1) monochannel gamma spectrometer, operating at photopeak counting (0.66 ± 0.07 MeV) (2) operating at integral counting (0.1 - 1.0 MeV), and (3) a scaler directly connected to the photomultiplier. Also taken into consideration were: the elimination of X-rays of 32 keV from the Ba-137m, gamma-rays back-scattering in the shield and in the source, and correction of dead time. After analysis of the results we came to the conclusion that it is perfectly feasible to substitute the monochannel gamma spectrometer for the system using a scaler.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2022-02-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.