• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.11.1981.tde-20231122-100859
Document
Auteur
Nom complet
Jefferson Mortatti
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 1981
Directeur
Titre en portugais
Determinação espectrofotométrica de baixos níveis de chumbo em águas naturais e extratos vegetais usando extração com solventes em sistema de injeção em fluxo
Mots-clés en portugais
ÁGUAS NATURAIS
ANÁLISE POR INJEÇÃO EM FLUXO
CHUMBO
ESPECTROFOTOMETRIA
EXTRATOS VEGETAIS
SOLVENTES
Resumé en portugais
Desenvolveu-se um método para a determinação de chumbo em águas naturais e extratos vegetais, através da reação com ditizona, empregando extração com tetracloreto de carbono em sistema analítico de injeção em fluxo. Foram estudados inicialmente, os fatores que incidiam diretamente sobre a sensibilidade do método proposto, como os efeitos da razão entre as fases aquosa e orgânica, tempo de extração, volume de amostra, concentração dos reagentes e acidez das amostras. Com o sistema de fluxo estabelecido, conseguiu-se uma velocidade analítica de 50 determinações por hora, podendo-se determinar até 20 partes por bilhão de Pb, com uma precisão de 98%. A média de recuperação obtida pelo teste de padronização interna foi da ordem de 94%.
Titre en anglais
Spectrophotometric determination of microgram amount of lead in natural waters and plant tissue using the solvent extraction technique in flow injection system
Resumé en anglais
An analytical method for the determination of lead in natural waters and plant tissue was developed using the dithizone reaction in carbon tetrachloride, and the flow injection system. The influence of organic-water phase ratio, the extraction time, the sample volume and acidity, the reagents concentration, were discussed, in relation with the sensitivity of the proposed methodology. An analytical speed of 50 samples per hour, and a sensitivity until 20 parts per billion of Pb was achieved, with a precision of 98%. The recovery by standard addition padronization, was around 94%.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-11-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.