Determinação espectrofotométrica de baixos níveis de chumbo em águas naturais e extratos vegetais usando extração com solventes em sistema de injeção em fluxo
Palabras clave en portugués
ÁGUAS NATURAIS
ANÁLISE POR INJEÇÃO EM FLUXO
CHUMBO
ESPECTROFOTOMETRIA
EXTRATOS VEGETAIS
SOLVENTES
Resumen en portugués
Desenvolveu-se um método para a determinação de chumbo em águas naturais e extratos vegetais, através da reação com ditizona, empregando extração com tetracloreto de carbono em sistema analítico de injeção em fluxo. Foram estudados inicialmente, os fatores que incidiam diretamente sobre a sensibilidade do método proposto, como os efeitos da razão entre as fases aquosa e orgânica, tempo de extração, volume de amostra, concentração dos reagentes e acidez das amostras. Com o sistema de fluxo estabelecido, conseguiu-se uma velocidade analítica de 50 determinações por hora, podendo-se determinar até 20 partes por bilhão de Pb, com uma precisão de 98%. A média de recuperação obtida pelo teste de padronização interna foi da ordem de 94%.
Título en inglés
Spectrophotometric determination of microgram amount of lead in natural waters and plant tissue using the solvent extraction technique in flow injection system
Resumen en inglés
An analytical method for the determination of lead in natural waters and plant tissue was developed using the dithizone reaction in carbon tetrachloride, and the flow injection system. The influence of organic-water phase ratio, the extraction time, the sample volume and acidity, the reagents concentration, were discussed, in relation with the sensitivity of the proposed methodology. An analytical speed of 50 samples per hour, and a sensitivity until 20 parts per billion of Pb was achieved, with a precision of 98%. The recovery by standard addition padronization, was around 94%.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-11-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.