• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.11.1987.tde-20210104-195234
Documento
Autor
Nombre completo
Luiz Carlos Ruiz Pessenda
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 1987
Director
Título en portugués
Determinação espectrofotométrica catalítica de molibdênio em digeridos vegetais com emprego de resina de troca iônica em sistema de injeção em fluxo
Palabras clave en portugués
ANÁLISE POR INJEÇÃO EM FLUXO
DETERMINAÇÃO
ESPECTROFOTOMETRIA
MOLIBDÊNIO
RESINAS DE TROCA IÔNICA
Resumen en portugués
Por intermédio de sistema de injeção em fluxo, foram estudados vários aspectos do método catalítico para a determinação espectrofotométrica de molibdênio em digeridas vegetais, empregando a reação de oxidação do iodeto pelo peróxido de hidrogênio em meio ácido. Uma coluna de resina catiônica foi incorporada ao sistema para remoção de interferentes. Inicialmente definiram-se as concentrações dos reagentes, o volume da alça de amostragem e comprimento dos reatores helicoidais de reação e mistura. Investigou-se também o efeito da temperatura. Após acoplamento da resina foram verificados o tempo necessário de amostragem, os efeitos da acidez na retenção do molibdênio, da concentração iônica da amostra, das interferências de ferro, fosfato, cromo, titânio, tungstênio e vanádio e das vazões e concentração de agentes eluentes. O sistema proposto permite a determinação de molibdênio em digeridos vegetais na faixa de 1,0 a 40,0 µg/l, com uma precisão superior a 98% e velocidade analítica em torno de 40 determinações por hora. No teste de exatidão, os resultados foram concordantes àqueles obtidos pela técnica de espectrometria de absorção atômica com forno de grafite.
Título en inglés
Spectrophotometric flow injection catalytic determination of molybdenum in plant digests using ion exchange resin
Palabras clave en inglés

Resumen en inglés
A spectrophotometric flow injection analytical method based on the catalytic action of molybdenum on the oxidation of iodide by hydrogen peroxide in acidic medium is proposed for the molybdenum determination in plant digests. A cation exchange resin column is incorporated into a flow injection system for removal of interferents. The following system variables were investigated and optimized: reagent concentrations, sample injection volume, mixing and reaction coil lengths, temperature, sampling time, pumping rate and concentration of eluting agents. The effects of interfering species and of the acidity of samples on the molybdenum retention by the ion exchange resin column were investigated. The proposed method is characterized by good precision (r.s.d. (2.0%), a sampling rate of about 40 samples per hour, and permits the determination of molybdenum in plant digests in the range 1.0 to 40.0 µg/l. The results compare well with those obtained by graphite furnace atomic absorption spectrometry.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-01-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.