• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.11.1987.tde-20210104-195234
Document
Auteur
Nom complet
Luiz Carlos Ruiz Pessenda
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 1987
Directeur
Titre en portugais
Determinação espectrofotométrica catalítica de molibdênio em digeridos vegetais com emprego de resina de troca iônica em sistema de injeção em fluxo
Mots-clés en portugais
ANÁLISE POR INJEÇÃO EM FLUXO
DETERMINAÇÃO
ESPECTROFOTOMETRIA
MOLIBDÊNIO
RESINAS DE TROCA IÔNICA
Resumé en portugais
Por intermédio de sistema de injeção em fluxo, foram estudados vários aspectos do método catalítico para a determinação espectrofotométrica de molibdênio em digeridas vegetais, empregando a reação de oxidação do iodeto pelo peróxido de hidrogênio em meio ácido. Uma coluna de resina catiônica foi incorporada ao sistema para remoção de interferentes. Inicialmente definiram-se as concentrações dos reagentes, o volume da alça de amostragem e comprimento dos reatores helicoidais de reação e mistura. Investigou-se também o efeito da temperatura. Após acoplamento da resina foram verificados o tempo necessário de amostragem, os efeitos da acidez na retenção do molibdênio, da concentração iônica da amostra, das interferências de ferro, fosfato, cromo, titânio, tungstênio e vanádio e das vazões e concentração de agentes eluentes. O sistema proposto permite a determinação de molibdênio em digeridos vegetais na faixa de 1,0 a 40,0 µg/l, com uma precisão superior a 98% e velocidade analítica em torno de 40 determinações por hora. No teste de exatidão, os resultados foram concordantes àqueles obtidos pela técnica de espectrometria de absorção atômica com forno de grafite.
Titre en anglais
Spectrophotometric flow injection catalytic determination of molybdenum in plant digests using ion exchange resin
Mots-clés en anglais

Resumé en anglais
A spectrophotometric flow injection analytical method based on the catalytic action of molybdenum on the oxidation of iodide by hydrogen peroxide in acidic medium is proposed for the molybdenum determination in plant digests. A cation exchange resin column is incorporated into a flow injection system for removal of interferents. The following system variables were investigated and optimized: reagent concentrations, sample injection volume, mixing and reaction coil lengths, temperature, sampling time, pumping rate and concentration of eluting agents. The effects of interfering species and of the acidity of samples on the molybdenum retention by the ion exchange resin column were investigated. The proposed method is characterized by good precision (r.s.d. (2.0%), a sampling rate of about 40 samples per hour, and permits the determination of molybdenum in plant digests in the range 1.0 to 40.0 µg/l. The results compare well with those obtained by graphite furnace atomic absorption spectrometry.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2021-01-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.