• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.11.2004.tde-13122004-101422
Documento
Autor
Nombre completo
Denis Cesar Cararo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2004
Director
Tribunal
Botrel, Tarlei Arriel (Presidente)
Coelho, Rubens Duarte
Duarte, Sergio Nascimento
Mendonça, Fernando Campos
Paterniani, Jose Euclides Stipp
Título en portugués
Manejo de irrigação por gotejamento para aplicação de água residuária visando a minimização do entupimento de emissores.
Palabras clave en portugués
águas residuárias
ar comprimido
cloração
irrigação por gotejamento - entupimento
Resumen en portugués
A escassez de água e a grande geração de esgoto doméstico com necessidade de tratamento estimulam o uso de águas residuárias na agricultura. A irrigação por gotejamento caracteriza-se como um sistema seguro para esta finalidade, mas possui como barreira tecnológica o entupimento dos gotejadores. Neste trabalho, objetivou-se selecionar modelos de gotejadores e manejos mitigadores do entupimento por uso de água residuária oriunda de tratamento secundário de esgoto doméstico. Desenvolveu-se o estudo em três etapas: (I) a caracterização de 15 modelos de gotejador novos, (II) a préseleção dos emissores e (III) a seleção da combinação manejo e modelo. Os manejos foram controle, cloração a 0,5 mg L-1 de cloro residual livre ao final da irrigação medido ao final do sistema, ar comprimido a 1,96 kPa na entrada dos emissores e a combinação de cloração e ar comprimido, utilizando-se filtragem de areia (De = 0,59 mm), disco (120 mesh) e tela (200 mesh) em todos os tratamentos. Procederam-se avaliações de vazão e cálculos de coeficiente de variação de vazão (CVq) e de grau de entupimento (GE). Os modelos apresentaram coeficiente de variação de fabricação aceitável e diferentes sensibilidades ao entupimento. O entupimento foi parcial, ocorreu de maneira desuniforme, independente da uniformidade de distribuição de água (UD) do emissor novo, e surgiu pela formação de biofilme bacteriano associado a sólidos dissolvidos. Houve aumentos de vazão em alguns modelos. A cloração reduziu o grau de entupimento ao longo do tempo e evitou o entupimento total em emissores. O modelo B associado à cloração apresentou a maior probabilidade de encontrar emissores na faixa de 5 % de variação de vazão em relação aos novos e o modelo M associado à filtragem ou a tratamentos com ar comprimido, as menores probabilidades. Os manejos mostraram-se semelhantes quanto ao GE e ao CVq e obtiveram-se valores de UD inferiores a 60 %, CVq superiores a 20 % e GE superiores a 5 %. Finalmente, de acordo com o objetivo, selecionou-se o modelo B associado à cloração como a combinação que melhor atenuou o entupimento dos emissores.
Título en inglés
Drip irrigation techniques to mitigate the dripper clogging in wastewater irrigation.
Palabras clave en inglés
chlorination
clogging
compressed air
drip irrigation
wastewater
Resumen en inglés
The sustainable management of water resources, given the current and projected severe water shortages, requires that appropriate methods of water usage be implemented. One of these is the application of treated wastewater to agricultural land using drip irrigation systems, which is safe and among the most resource efficient methods of irrigation. However, the use of drip irrigation with wastewater is constrained by the potential for clogging in the emitters. To elucidate the mechanism of clogging, fifteen drip emitters models from different manufacturers were tested with secondary treated wastewater in the laboratory and two field experiments were conducted to evaluate emitters and treatments according to the degree of clogging (DC) and flow rate coefficient of variation (CVq). The treatments were control (filtrage only), chlorination (0.5 mg L-1 free residual chlorine injected at the end of each irrigation cycle), compressed air (1.96 kPa in the inlet drippers) and the chlorine and compressed air combination. The manufacture coefficient of variation was acceptable and different clogging susceptibility. The clogging was partial, non-uniform and was caused by biofilm with dissolved solids. Some drippers with overflow rates were noted. The chlorination decreased clogging overtime and reduced the complete clogging. The dripper model B (pressure compensated, flat and inserted in the line, with rectangular elastic membrane over a 30 mm passageway, 0.8 mm narrowest aperture, 1.61 L h-1 under 98 kPa) with chlorination was identified as having the best performance, with the highest number of emitters with a flow rate within five percent of the flow rate when new, and the dripper model M with chlorination was the worst performance with the lowest percent. The filtrage, chlorine and air treatments did not have a statistically significant affect in the DC or CVq. Distribution uniformities higher than 60 %, CVq higher than 20 % and DC higher then 5 % were found. Finally, according to the purposed, It was selected the dripper model B with chlorination as the best combination to mitigate the clogging
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
denis.pdf (2.60 Mbytes)
Fecha de Publicación
2004-12-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.