Influência do espaçamento entre coletores, do número de linhas radiais e da altura do emissor no coeficiente de uniformidade de Christiansen para pivô central
Mots-clés en portugais
IRRIGAÇÃO POR PIVÔ CENTRAL
Resumé en portugais
Devido ao fato do equipamento pivô central adaptar-se a diferentes condições edafoclimáticas, torna-se necessário a realização de avaliações de seu desempenho operacional. O objetivo deste trabalho foi analisar a influência do espaçamento entre coletores, do número de linhas radiais de coletores e da altura dos emissores, em relação à superfície de captação dos coletores, no coeficiente de uniformidade de Christiansen para a avaliação da uniformidade de distribuição da água por pivô central. Foram utilizadas cinco espaçamento entre coletores (2,5 m, 5,0 m, 7,5 m, 10,0 m e 12,5 m), quatro combinações de número de linhas radiais (1, 2, 3 e 4 linhas radiais) e três alturas de emissores (1,10 m, 1,65 m e 3,20 m). De acordo com os resultados encontrados e nas condições em que o trabalho foi realizado, concluiu-se que: - não houve efeito significativo dos espaçamentos entre coletores sobre o coeficiente de uniformidade de Christiansen. - a utilização de duas linhas radiais constituiu a melhor condição para a determinação do coeficiente de uniformidade de Christiansen. - a altura dos emissores apresentou efeito significativo sobre o coeficiente de uniformidade de Christiansen.
Titre en anglais
The influence of collector spacing, number of radial lines and spray height on the water distribution uniformity under center pivot irrigation system
Resumé en anglais
Due the center-pivot irrigation system adapte easily to different topographical and climate conditions, so it is necessary to evaluate the equipment performance under field conditions. The objective of this work is to analyze the influence of collector spacing, the number of radial lines and the spray height on the Christiansen uniformity coefficient of a center-pivot irrigation system. It was utilized five collector spaces (2,5 m, 5,0 m, 7,5 m, 10,0 m and 12,5 m), four number combination of radial line (1, 2, 3 and 4) and three spray heights (1,10 m, 1,65 m and 3,20 m). The following conclusions were found: - the five spaces collector studied didn't show statistics difference for the Christiansen uniformity coefficient. - two radial line was the better condition to determine the Christiansen uniformity coeficiente - all spray height analyzed showed statistics difference for the Christiansen uniformity coefficient.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2022-02-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.