• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.11.1998.tde-20231122-092736
Document
Auteur
Nom complet
Luiz Antônio Alves José
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 1998
Directeur
Titre en portugais
Atividade do Baculovírus de Autographa californica (Speyer) - vEGTDEL sobre Heliothis virescens (F.)
Mots-clés en portugais
BACULOVÍRUS
CONTROLE BIOLÓGICO
LAGARTA-DA-MAÇÃ-DO-ALGODOEIRO
VÍRUS DA POLIEDROSE NUCLEAR
Resumé en portugais
Diferentes fatores do ambiente foram testados visando verificar a ação isolada de cada um sobre a atividade do vírus da poliedrose nuclear de Autographa californica (Speyer) vEGTDEL formulado em lagartas de H. virescens. Foram estimados os valores de CL90-99 em teste de laboratório, sendo que o valor da CL90 observado e que foi adotado para a realização de todos os demais bioensaios foi 1,3 x 106 CIP(corpos de inclusão poliédrico)/ml ou 2,54 x 1011 CIP/ha, considerando-se um volume de calda de 200 l/ha. Para todos os testes, foram utilizadas lagartas de H. virescens no 1° instar com a finalidade de se observar a atividade do vírus através dos níveis de mortalidade larval. Foram testados 6 níveis de pH da água utilizada para a diluição do vírus (4,0; 5,0; 6,0; 7,0; 8,0 e 9,0), com o objetivo de se avaliar a ação do tempo de permanência do vírus (horas) sob diferentes pHs. Os tempos utilizados foram 0,3, 6, 12, 24, 48 e 72 horas. A ação da temperatura do ambiente sobre a atividade do patógeno foi testada utilizando-se vasos contendo plantas de algodão pulverizadas com suspensão contendo o vírus na concentração 1,2 x 1012 CIP/ha. Estas plantas foram mantidas em BOD nas temperaturas 20, 24, 27, 30, 32, 35, 37, 40 e 42°C por 8 horas na ausência de luz. A ação do armazenamento sobre a atividade do baculovírus foi avaliada tomando-se como variáveis o tipo de embalagem (frasco de alumínio, frasco de vidro escuro, frasco plástico escuro), a temperatura (8, 25 e 30°C) e o período de armazenamento (30, 60, 90 e 120 dias). Foi realizado ainda um experimento visando observar a ação de alguns adjuvantes utilizados para aumentar a efetividade do vírus em condições de campo. Os adjuvantes testados foram Kinetic® (0,2%), Mirasperse® (0,5%), Coax® (3,5%) e carvão vegetal (50%) em misturas com o baculovirus formulado. Concluiu-se que pH da água e a temperatura ambiente não afetaram a taxa de mortalidade final. A temperatura de 8°C se mostrou satisfatória para o armazenamento do baculovirus por 120 dias. O tipo de embalagem afetou o armazenamento quando a temperatura foi acima de 8°C. Dos adjuvantes testados, observou-se um aumento no período residual do vírus quando se utilizaram Coax® e carvão vegetal.
Titre en anglais
Activity of baculovirus of Autographa californica (Speyer) - vEGTDEL on Heliothis virescens (F.)
Resumé en anglais
Different environment factors were tested in order to verify their effect on the activity of nuclear polyhedrosis virus (NPV) from the Autographa californica (Speyer) - vEGTDEL formulated. The LC90-99 values were estimated through laboratory tests. The value 1,3 x 106 PIB/ml or 2,54 x 104 PIB/ha corresponding to the LC90 was used for all the bioassays. Larvae of the H. virescens on first instar were used in order to observe the activity of the virus evaluating their mortality rate. Six pH ranges of the water (4.0, 5.0, 6.0, 7.0, 8.0 and 9.0) were tested for the virus dilution aiming the determination of the effect of the virus exposition time on each pH. The virus exposure intervals tested were 0, 3, 6, 12, 24, 48 and 72 hours. The effect of the environment temperature on the virus activity was tested using cotton plants cultivated in pots sprayed with a virus suspension at the rate 1,2 x 1012 PIB/ha. These plants were maintained in a BOD at temperature of 20, 24, 27, 30, 32, 35, 37, 40 and 42°C for 8 hours in the absence of light. The effect of the storage on the baculovirus activity was evaluated by varying the type of package (aluminum flask, dark glass flash and dark plastic flask), the storage temperature (8, 24 and 30°C) and period of time (30, 60, 90 and 120 days). The acute and residual activites of the virus were also tested. Included in the formulation matrix mixed were kinetic® (0,2%), Mirasperse® (0,5%), Coax® (3.5%) and Charcoal (50%). The water pH and the environment temperature didn’t affect the final mortality rate. The best result for the virus storage for 120 days was obtained by the temperature of 8°C. Temperatures over 8°C affected the H. virescens virus mortality regardless of the packaging type. Coax® and Charcoal increased the virus residual activity.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-11-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.