Aplicação da dosimetria termoluminescente em estudos de campos de radiação
Mots-clés en portugais
DOSIMETRIA TERMOLUMINESCENTE
FLUORETO DE LÍTIO
RADIAÇÃO GAMA
Resumé en portugais
Com o intuito de se difundir a técnica da dosimetria termoluminescente, foi desenvolvido um estudo para se obter as curvas de dose profunda em diferentes materiais, quando expostos a um campo de radiação gama, utilizando-se para isso dosímetros termoluminescentes de fluoreto de lítio, LiF. Fez-se um estudo do fator de conversão de dose do fluoreto de lítio para os materiais estudados de interesse agronômico: água, madeira e solo. Foram levantadas as curvas de dose absorvida em função da profundidade, para cada material e determinadas as equações de regressão que melhor se ajustam às curvas. Concluiu-se que, nos três materiais estudados, a dose de radiação absorvida apresenta uma variação acentuada com a profundidade e que podem ser correlacionadas através de uma regressão exponencial.
Titre en anglais
Use of thermoluminescent dosimetry in gamma radiation fields studies
Resumé en anglais
The depth-dose curves for gamma rays in material of interest to agronomy were obtained using lithium fluoride thermoluminescent dosimeters. The dose conversion factors for LiF were determined from curves of the absorbed dose versus depth in water, wood and soil. Mathematical equations were chosen to best fit these curves. In the view of the results we came to the conclusion that in the studied materials the absorbed radiation dose presents a great variation to the depth and could be correlated through of the exponential regression.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Carron-Wilson.pdf (4.60 Mbytes)
Date de Publication
2023-11-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.