Investigação geofísica 2D e 3D com aplicação em meio ambiente: estudo sobre uma área de disposição de resíduos de óleo lubrificante no município de Ribeirão Preto - SP
Mots-clés en portugais
Eletrorresistivdade
GPR e contaminantes orgânicos.
Polarização Induzida
Potencial Espontâneo
Resumé en portugais
A geofísica tem mostrado eficácia em identificar áreas contaminadas por derivados de petróleo, contribuindo para tornar mais efetivos os programas de sondagem voltados à coleta de amostras e instalação de poços de monitoramento. O presente trabalho apresenta resultados de investigações geofísicas em uma área de disposição de resíduos de re-refino de óleo lubrificante localizada no município de Ribeirão Preto, no Estado de São Paulo. Na área de estudo os resíduos foram dispostos em quatro cavas com um volume total de aproximadamente 25.000 m3, em área de afloramento de arenitos da Formação Botucatu e basaltos da Formação Serra Geral. As cavas foram totalmente preenchidas com resíduos por aproximadamente 25 anos e não foi usado nenhum tipo de impermeabilização na base e laterais destas cavas. O objetivo do trabalho foi o estudo de uma metodologia geofísica de aquisição e modelagem de dados 3D com os métodos da eletrorresistividade e polarização induzida para a caracterização geoambiental da área de estudo, seguido pelos métodos potencial espontâneo e ground penetrating radar (GPR). A aquisição de dados 3D, a partir de uma série de levantamentos elétricos 2D, mostrou-se eficaz em mapear variações de resistividade e cargabilidade em três dimensões, mostrando em subsuperfície o comportamento dos contaminantes. As anomalias condutivas na zona saturada e zona não saturada estão relacionadas à contaminação gerada pelo processo de biodegradação. Em geral, as cavas com resíduos são caracterizadas por baixos valores de cargabilidade. Nos levantamentos elétricos 2D são observadas anomalias condutivas abaixo das cavas coincidentes com a atenuação do sinal eletromagnético do GPR, evidenciando a contaminação do meio, bem como o aumento da polarização à medida que se afasta da fonte de contaminação. O método potencial espontâneo, também, possibilitou o mapeamento da contaminação, que é associada às anomalias negativas de potencial espontâneo e evidencia atividade geoquímica no local. O GPR foi o método mais eficiente na identificação da geometria das cavas, com exceção da cava 1, cuja base não é bem caracterizada pelo sinal GPR. As análises diretas de amostras de solo e água subterrânea confirmam a contaminação. Nas análises de solo, baixas concentrações de alguns hidrocarbonetos policíclicos aromáticos foram encontradas, principalmente naftaleno e fenantreno. Nas amostras de água, foi confirmado contaminação da água subterrânea por chumbo (Pb). O processo de biodegradação é confirmado pela existência de microorganismos (bactérias), como constatado na análise biológica das amostras de solo coletadas em um ponto específico, onde assinaturas geofísicas sugerem contaminação. Os métodos geofísicos utilizados afirmam-se como uma ferramenta de grande potencial na caracterização geoambiental, juntamente com os métodos de investigação direta neste caso de estudo, e podendo ser aplicados no estudo de áreas similares.
Titre en anglais
2D and 3D geophysical investigation with environmental applicatiom: study on a lubricant oil waste disposal area in the municipal of Ribeirão Preto - SP.
Mots-clés en anglais
Eletrical Resistivity
GPR and Lubicant Oil.
Induced Polarization
Sel Potential
Resumé en anglais
Geophysics has been shown to be effective in identifying areas contaminated by oil products, contributing to the greater efficiency of soundings programs and the installation of monitoring wells. The present work presents results of geophysical investigations in a lubricant oil waste area located in the municipality of Ribeirão Preto, São Paulo State, Brazil. In the study area the waste was disposed of in four trenches with a total volume of about 25.000 m3. This area is situated on the geological domains of the basaltic spills of the Serra Geral Formation and the sandstones of the Botucatu Formation. The trenches were totally filled with waste over approximately 25 years and no protection liners were used in the bottom or laterals of the trenches. The goal of the study was the acquisition and modeling of 3D data with the electroresistivity and induced polarization methods for the environmental characterization of the study area, followed by self potential and ground penetrating radar methods (GPR). The acquisition of 3D data, from a series of 2D electrical surveys, was effective in mapping variations of resistivity and chargeability in three dimensions, showing in the subsurface the behavior of contaminants. The conductive anomalies in the saturated zone and unsaturated zone were related to contamination generated by the biodegradation process. In general, the trenches with waste were characterized by low values of chargeability. In 2D electrical surveys, conductive anomalies were observed below the trenches coincident with the attenuation of the electromagnetic signal of the GPR, indicating the contamination of the environment and increased polarization from the contamination source. The self potential method also allowed mapping of the contamination, which is associated with negative anomalies of self potential and evidence of geochemical activity in the locale. GPR was the method most efficient in the identification of the geometry of the trenches, except in the trench 1, in which the base is not delineated by a GPR signal. A direct analysis of the soil and groundwater samples confirmed the contamination. In the soil analysis, low concentrations of several polycyclic aromatic hydrocarbons were found, mainly naphthalene and phenanthrene. In the water samples, there was confirmed contamination of the groundwater by lead (Pb). The biodegradation process was confirmed by the presence of microorganisms (bacteria), as evidenced in a biological analysis of soil samples collected at a specific point, where geophysical signatures suggested contamination. The geophysical methods used were an excellent tool for an environmental characterization, and together with the direct methods of investigation in this case study and can be applied in the study of similar areas.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
LAGO_2009.pdf (38.76 Mbytes)
Date de Publication
2011-02-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.