• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.16.2013.tde-06062013-143321
Document
Author
Full name
Sandra Rachel Moscati
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2013
Supervisor
Committee
Baring, Joao Gualberto de Azevedo (President)
Oliveira, Claudia Terezinha de Andrade
Passeri Junior, Lineu
Title in Portuguese
Desempenho acústico de templos e igrejas: subsídios à normalização
Keywords in Portuguese
Acústica arquitetônica
Desempenho
Igrejas
Templos
Abstract in Portuguese
Este trabalho aborda a problemática da acústica de igrejas construídas a partir da segunda metade do século XX por meio da revisão bibliográfica e do estudo de caso de três igrejas na cidade de São Paulo. O objetivo da pesquisa é estudar o desempenho dos espaços sonoros internos e externos de três templos, escolhidos como amostras, com base na normalização brasileira vigente. Avaliaram-se por meio de medições acústicas o tempo de reverberação nas naves, o nível de ruído ambiente em frente às igrejas, o nível de ruído ambiente interno nas naves das igrejas, bem como o nível sonoro nas naves e em frente às igrejas durante os cultos religiosos. Com isso procurou-se realizar o levantamento dos problemas enfrentados pelas igrejas em relação à qualidade acústica nas naves e as possíveis interferências que causam à comunidade vizinha, quanto aos níveis sonoros emitidos. O equipamento de medição utilizado foi um analisador profissional de áudio. A arquitetura das igrejas e sua localização e implantação na cidade são determinantes para a qualidade acústica das naves e os níveis sonoros emitidos no entorno. A pesquisa revelou que o nível de ruído ambiente em frente às igrejas interfere na relação sinal/ruído nas naves e que a interferência do nível sonoro emitido no ambiente externo pelas igrejas durante o seu funcionamento depende da localização, condições de uso e sobretudo de suas condições arquitetônicas. Estas condições, quando mal resolvidas, decorrem de projetos em que os requisitos acústicos não foram observados ou deixados de lado durante a execução da obra.
Title in English
Acoustic performance evaluation of 3 churches, based on brazilian normalization
Keywords in English
Architectural acoustics
Churches
Performance
Temples
Abstract in English
This paper discusses the acoustic of churches built from the second half on of the twentieth century based on literature survey and the specific case study of three churches in the city of São Paulo. The objective of this research is to study the performance of internal and external sound in three temples, chosen as samples, based on the Brazilian standards in force. Measurements of the acoustic reverberation time in the aisle, the internal and external noise level of the environment, as well as in front of the churches during religious services were performed. Therefore, the survey of the problems faced by the churches regarding the acoustic quality in the aisles and possible interferences that it may cause to the surrounding community were evaluated. The measuring equipment used was a professional audio analyzer. The architecture of the churches, their implementation and location in the city are crucial to the acoustic quality of the aisles and sound levels emitted to the environment. The research revealed that the ambient noise level in front of the churches interferes in the signal / noise in aisles and the interference of sound emitted by the churches in the external environment during operation depends on the location, conditions of use and mainly its architectural conditions. These conditions, if poorly solved, result from projects in which the acoustic requirements were not observed or left out during the execution of the building
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-07-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.