• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.17.2012.tde-22092012-231314
Documento
Autor
Nombre completo
Marcelo Ferreira Cassini
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2012
Director
Tribunal
Tucci Junior, Silvio (Presidente)
Ortiz, Valdemar
Ribeiro, Jose Genilson Alves
Silva, Gyl Eanes Barros
Tirapelli, Luis Fernando
Título en portugués
Correlação entre a espectroscopia de fluorescência induzida pelo laser e as alterações histológicas na isquemia e reperfusão renal em ratos
Palabras clave en portugués
biópsia renal
Espectroscopia de fluorescência
isquemia e reperfusão renais
transplante renal.
Resumen en portugués
Introdução: O transplante renal é amplamente reconhecido como a melhor forma de tratamento para os pacientes que necessitam de terapia de substituição renal. Frequentemente a equipe transplantadora se depara com a difícil questão de determinar se órgãos, provenientes de doadores falecidos e limítrofes ou em parada cardíaca, estão aptos para serem transplantados. É difícil quantificar a intensidade do dano provocado pela isquemia no enxerto a ser utilizado, especialmente se o doador apresentou quadro de instabilidade hemodinâmica com queda significativa da perfusão tecidual e aumento do risco de diminuir a função do enxerto e afetar adversamente sua sobrevida. Desta forma torna-se justificável a utilização da técnica de espectroscopia de fluorescência induzida pelo laser, na tentativa de se avaliar a correlação entre os seus achados e o grau de lesão histológica renal experimental, uma vez que se trata de um método objetivo, não invasivo, rápido e em tempo real que, futuramente, pode ser aplicada nos transplantes renais em humanos. Objetivos: Avaliar a correlação entre os dados da espectroscopia de fluorescência induzida pelo laser e alterações histológicas na isquemia e reperfusão renal em ratos, e se existe diferença significativa na leitura da espectroscopia entre os polos superior, inferior e o terço médio. Materiais e Métodos: Foram utilizados 33 ratos (Rattus norvegicus) machos adultos da linhagem Wistar que, depois de anestesiados, tiveram seus rins esquerdos abordados. Inicialmente os rins foram submetidos à detecção da espectroscopia de fluorescência dos pólos superiores, inferiores e terços médios. As excitações foram geradas por lasers com comprimentos de onda de 408, 442 e 532 nm. Em seguida os pedículos renais esquerdos foram dissecados, isolados e clampeados com auxílio de mini-pinça vascular. Então, os animais foram divididos aleatoriamente em três grupos isquêmicos de 30, 60 e 120 minutos de isquemia quente. Em cada um dos grupos, os rins foram novamente analisados pela espectroscopia de fluorescência, bem como após 5 minutos de reperfusão, utilizando novamente feixes excitatórios com os mesmos comprimentos de onda, nas mesmas regiões renais. Posteriormente os rins esquerdos foram coletados e enviados para estudo histológico. Resultados: O tempo de isquemia mostrou forte influência com a graduação histológica. Com 30 minutos de isquemia, nenhum comprimento de onda (408, 442 e 532 nm) apresentou correlação com a graduação histológica (p = 0,81; p = 0,11; p = 0,21, respectivamente). Com 60 minutos de isquemia, o laser de excitação de 532 nm (na fase de reperfusão) apresentou coeficiente de correlação negativa significativa (r = - 0,61) com a graduação histológica. Na isquemia de 120 minutos, o laser com 442 nm de comprimento de onda (na fase de reperfusão) mostrou o coeficiente de correlação negativa significativa (r = - 0,73) com a graduação histológica. O terço médio renal apresentou média estatística superior à dos polos (p < 0,001) na leitura da espectroscopia de fluorescência. Conclusões: Há correlação entre os dados da espectroscopia de fluorescência induzida pelo laser e as alterações histológicas na isquemia renal em ratos, sendo necessário, durante a investigação, analisar apenas o terço médio renal.
Título en inglés
Correlations between the laser-induced fluorescence spectroscopy and histological changes in kidney ischemia and reperfusion in rats.
Palabras clave en inglés
Fluorescence spectroscopy
renal biopsy
renal ischemia-reperfusion
renal transplant.
Resumen en inglés
Introduction: Renal transplantation is widely recognized as the best form of treatment for patients who require renal replacement therapy. Often, the transplant team is faced with a difficult question, if organs from deceased marginal donors or non-heart beating donors are able to be transplanted. It is difficult to quantify the intensity of damage caused by ischemia in the graft to be used, especially if the donor had hemodynamic instability with a significant decrease of the tissue perfusion and an increased of the risk of diminishing the graft function which could affect adversely its survival. Thus it is justified to use the technique of laser-induced fluorescence spectroscopy, to assess the correlations between its results and the histological grade in experimental renal injury, since it is an objective, non-invasive, fast and in real-time analysis, which can be applied, in the future, in human kidney transplants. Objectives: To evaluate the correlation between the data of laser-induced fluorescence spectroscopy and histological changes in kidney ischemia and reperfusion in rats, and if there are significant differences of reading between the upper and lower poles and the middle area of such kidneys. Materials and Methods: We used 33 adults male rats (Rattus norvegicus) of Wistar strain, which after anesthetized, had their left kidney addressed. Initially such kidneys were submitted to detection of the fluorescence spectroscopy of the upper pole, lower pole and the middle area. Excitations were generated by lasers having wavelengths of 408, 442 and 532 nm. Then the left renal pedicles were dissected, isolated and clamped. Then the animals were randomized into three ischemic groups of 30, 60 and 120 minutes. In each group, the kidneys were analyzed by fluorescence spectroscopy for the second time, and again after 5 minutes of reperfusion, using excitatory beam with same wavelength, at the poles (upper and lower) and the middle area of the kidneys. Later, the left kidney were collected and sent for histological examination. Results: The ischemia time showed a strong influence on the histological grade. With 30 minutes of ischemia, no wavelength (408, 442 and 532 nm) was correlated with the histological lesions (p = 0.81, p = 0.11, p = 0.21, respectively). With 60 minutes of ischemia, the laser excitation of 532 nm (in the reperfusion phase) showed a significant negative correlation coefficient (r = - 0.61) with the histological grading. In 120 minutes of ischemia, laser with 442 nm wavelength (in the reperfusion phase) showed a significant negative correlation coefficient (r = - 0.73) with the histological grade. The middle area of the kidneys showed a higher average statistically (p< 0,001) than the poles in the reading of fluorescence spectroscopy. Conclusions: There is a strong correlation between the data of laser-induced fluorescence spectroscopy and the histological changes in rats renal ischemia, being necessary, during the investigation, to analyze only the middle area of the kidneys.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-12-11
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • CASSINI, M.F., et al. Evaluation by Fluorescence Spectroscopy of the Most Appropriate Renal Region for Obtaining Biopsies : A Study in the Rat [doi:10.1016/j.transproceed.2013.01.059]. Transplantation Proceedings [online], 2013, vol. 45, n. 5, p. 1761-1765.
  • CASSINI, M.F., et al. Fluorescence Spectroscopy in Renal Ischemia and Reperfusion : Noninvasive Evaluation of Organ Viability [doi:10.1016/j.transproceed.2012.10.054]. Transplantation Proceedings [online], 2013, vol. 45, n. 5, p. 1715-1719.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.