• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2016.tde-29052015-101117
Documento
Autor
Nombre completo
Camila de Almeida
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2014
Director
Tribunal
Riberto, Marcelo (Presidente)
Chaves, Thais Cristina
Lourenço, Charles Marques
Título en portugués
Aplicabilidade, validação e reprodutibilidade do Spinal Cord Independence Measure version III (SCIM III) nos pacientes com paraparesia espástica
Palabras clave en portugués
Paraparesia espástica
Reprodutibilidade dos testes
Validade dos testes
Resumen en portugués
Objetivo: verificar a aplicabilidade, reprodutibilidade e validade do SCIM III nos pacientes com paraparesia espástica. Método: estudo transversal incluindo 30 sujeitos (66% mulheres; 41,5±14,7 anos) com paraparesia espástica de etiologia genética, infecciosa ou a esclarecer que foram avaliados pela análise computadorizada da marcha, versão brasileira da SCIM III (0-100 pontos), MIF (18-126 pontos), por 2 examinadores (A e B) no mesmo dia e 1 semana depois (A). Resultados: o coeficiente de correlação intraclasse (CCI) para o uso da SCIM III indicou boa reprodutibilidade intra e inter-examinadores (CCI=0,9). A correlação de Spearman entre a SCIM III e a parte motora da MIF foi considerada adequada e estatisticamente significante (Spearman=0,6; p=0,001). A correlação entre as subescalas da SCIM III e os domínios da MIF foi considerada forte e significante para auto-cuidado (Spearman=0,8; p0,001) e moderada para transferências (Spearman=0,6; p=0,0005) e locomoção (Spearman=0,6; p=0,0006). A subescala mobilidade da SCIM III mostrou correlação positiva e significante para cadência (Spearman=0,8; p0,001), velocidade da marcha (Spearman=0,7; p0,001) e comprimento do passo (Spearman=0,6; p0,001). Conclusões: A SCIM III é um instrumento de avaliação funcional reprodutível intra e inter examinadores e capaz de avaliar o nível de independência dos indivíduos com paraparesia espástica. O SCIM III é mais sensível que a MIF, especialmente para pacientes com maior independência. Cadência, velocidade de marcha e comprimento do passo se correlacionaram com a subescala mobilidade
Título en inglés
Applicability, validation and reproducibility of the Spinal Cord Independence Measure version III (SCIM III) in patients with spastic paraplegia
Palabras clave en inglés
Reproducibility of tests
Spastic paraparesis
Validity of tests
Resumen en inglés
Purpose: to verify the applicability, reproducibility, and validity of the SCIM III patients with non-traumatic spastic paraplegia. Method: The cross-sectional study included 30 subjects (66% females; 41.5 ± 14.7 y) older with spastic paraparesis of any etiology were assessment by computerized gait analysis and with the Brazilian versions of SCIM III (0-100 points), FIM (18-126 points) by 2raters (A and B) at the same day and 1 week later (A). Results: The intraclass correlation coefficient (ICC) for the use of SCIM III indicated good intra and inter-evaluator reproducibility (ICC = 0.9). Correlation between the SCIM III and the motor FIM was appropriate (Spearman=0.6; p0.001). SCIM III subscales and the FIM domains correlated strongly for self-care (Spearman=0.8; p0.001), moderately for transfers (Spearman=0.6; p=0.0005) and locomotion (Spearman=0.6; p=0.0006). SCIM III mobility subscale positively correlated with the cadence (Spearman=0.8; p0.01), gait speed (Spearman=0.7; p0.01), and step length (Spearman=0.6;p0.01). Conclusions: SCIM III is a reproducible functional assessment instrument and capable of evaluating the level of independence of the individual with spastic paraplegia. The SCIM III is more sensitive than the FIM for non-traumatic spastic paraplegic patients with higher levels of independence. Linear gait parameters correlated with its mobility subscale.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-01-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.