• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2019.tde-05082019-130526
Document
Author
Full name
Eduardo Deroide do Nascimento
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2019
Supervisor
Committee
Simão, Marcelo Novelino (President)
Barbosa, Marcello Henrique Nogueira
Herrero, Carlos Fernando Pereira da Silva
Salim, Rodrigo
Title in Portuguese
Avaliação do efeito do uso de sequências sensíveis a líquido na classificação das alterações do tipo Modic na coluna lombar
Keywords in Portuguese
Coluna lombar
Disco intervertebral
Modic
Abstract in Portuguese
As alterações de sinal no osso subcondral dos corpos vertebrais foram descritas primeiramente por Modic, correlacionando o espectro das alterações da medula óssea no corpo vertebral relacionadas a discopatias degenerativas. O Modic tipo I representa a alteração de sinal do tipo edema, já o Modic II representa a alteração de sinal com padrão de lipossubstituição e o Modic III representa alteração de sinal relacionada a esclerose óssea. O objetivo primário deste estudo foi avaliar se há alteração na detecção dos padrões da classificação Modic na coluna lombar comparando a técnica Dixon com o protocolo tradicional. Como objetivo secundário avaliamos a correlação intra-observador e interobservador. O estudo foi realizado de forma retrospectiva com a inclusão de pacientes cujas ressonâncias magnéticas (RM) foram realizadas na Central de Diagnóstico Ribeirão Preto (CEDIRP). Dois médicos radiologistas de forma independente classificaram as alterações do tipo Modic permitindo uma avaliação interobservador e um dos radiologistas realizou uma segunda análise dos exames possibilitando uma avaliação intra-observador. Os resultados evidenciaram que a técnica Dixon apresentou superioridade na detecção do Modic I em todas as análises e também apresentou médias mais altas da espessura das alterações no osso subcondral. Houve correlações intra-observador moderadas e substanciais no protocolo tradicional e substanciais a altas com a técnica Dixon. A correlação interobservador demonstrou uma correlação moderada na avaliação deste tipo de alteração nos platôs superior e inferior de L3 e correlação inversa e não significativa para a o platô superior de L5 utilizando o protocolo tradicional. Já a correlação interobservador com a técnica Dixon evidenciou concordância perfeita entre os observadores na avaliação de tipo de alteração de sinal no osso subcondral do platô inferior de L1, correlação inversa para o platô inferior de L3 e superior de L4, correlação substancial entre o platô inferior de L2, platô inferior de L5 e superior de L5. Concluímos que a técnica Dixon apresentou superioridade na detecção do Modic I em relação ao protocolo tradicional, assim como permitiu detectar médias mais altas da espessura das alterações no osso subcondral. Também conclui-se que houve boa reprodutibilidade intra-observador e correlação interobservador variável entre os platôs vertebrais analisados
Title in English
Evaluation of the effect of the use of fluid sensitive sequences on the classification of Modic type endplate changes in the lumbar spine
Keywords in English
Intervertebral disc
Lumbar spine
Modic
Abstract in English
Signal changes in the subchondral bone of the vertebral bodies were first described by Modic, correlating the spectrum of bone marrow changes in the vertebral body to degenerative disc diseases. Modic type I represents the change of edema type signal, while Modic II represents the change of signal with liposubstitution pattern and Modic III represents signal change related to bone sclerosis. The main objective of this study was to evaluate if there is difference in the detection of Modic classification in the lumbar spine comparing the Dixon technique with the traditional protocol. We evaluated the intraobserver and interobserver correlation as a secondary objective. The study was performed retrospectively, including patients whose magnetic resonance imaging (MRI) was performed at the Ribeirão Preto Diagnostic Center (CEDIRP). Two radiologist physicians independently classified the Modic type endplate changes allowing an interobserver evaluation and one of the radiologists performed a second analysis of the exams making possible an intraobserver evaluation. The results showed that the Dixon technique presented superiority in the detection of Modic I in all the analyzes and also presented higher averages of the thickness of the alterations in the subchondral bone. There were moderate and substantial intraobserver correlations in the traditional protocol and substantial to high Dixon technique. The interobserver correlation was moderate in the evaluation of this type of alteration for the upper and lower plateau of L3 and inverse and nonsignificant for the upper plateau of L5 using the traditional protocol. On the other hand, the interobserver correlation with the Dixon technique showed perfect agreement among the observers in the evaluation of type of signal change in the subchondral bone of the lower plateau of L1, an inverse correlation for the lower plateau of L3 and higher of L4, a substantial correlation between the lower plateau of L2, lower of L5 and higher of L5. We conclude that the Dixon technique presented superiority in the detection of Modic I compared with the traditional protocol, as well as allowed the detection higher averages of the thickness of alterations in the subchondral bone. It was also concluded that there was good intraobserver reproducibility and a variable interobserver correlation between the vertebral plateaus analyzed
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-08-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.