• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2014.tde-04122014-094332
Document
Auteur
Nom complet
Loana Henriquez Sanchez
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2014
Directeur
Jury
Tsuha, Cristina de Hollanda Cavalcanti (Président)
Carvalho, David de
Cintra, José Carlos Angelo
Titre en portugais
Avaliação de soluções alternativas para o aumento de capacidade de carga de fundações por estacas helicoidais
Mots-clés en portugais
Capacidade de carga
Estaca helicoidal
Fundações
Injeções com calda de cimento
Prova de carga
Resumé en portugais
A utilização de estacas helicoidais como fundação de linhas de transmissão de energia elétrica tem aumentando significativamente no Brasil. No entanto, em alguns casos de obra, a camada de solo adequada para se instalarem as hélices da estaca encontra-se em profundidade economicamente inviável para o uso deste tipo de fundação. Esta foi a razão que motivou a presente pesquisa, que tem como objetivo avaliar soluções para a instalação de estacas helicoidais mais curtas, ancoradas em solo de capacidade inferior à necessária para atender às cargas de projeto. Nesta dissertação, foram avaliadas duas soluções alternativas para o aumento de capacidade de carga de fundações por estacas helicoidais, para os casos de carregamento de tração e compressão. A primeira alternativa verificada foi a injeção de calda de cimento em torno das hélices da ponta da estaca. A segunda solução testada foi o preenchimento com argamassa em torno da haste da estaca acima das hélices. Foram realizadas na presente pesquisa nove provas de carga (cinco de tração e quatro de compressão): três em estacas helicoidais convencionais, quatro em estacas helicoidais com injeção de calda de cimento e duas em estacas helicoidais com fuste de argamassa. Após a realização de provas de carga nas estacas, estas foram exumadas para se verificar a forma da coluna de argamassa e as formas de bulbos resultantes das injeções realizadas com calda de cimento. A partir dos resultados dos ensaios, foi verificado que a capacidade de carga da estaca á tração pode ser aumentada usando-se as alternativas testadas. Porém, são necessários mais ensaios para avaliar a eficiência destes procedimentos em diferentes condições de solo e configuração de estacas.
Titre en anglais
Evaluation of alternative solutions to increase helical pile capacity
Mots-clés en anglais
Foundation
Helical pile
Pile capacity
Pile load test
Water-cement injection
Resumé en anglais
The use of helical piles as foundation for transmission lines has increased significantly in Brazil. However, in some sites, the soil layer suitable for installing the pile helices are considerably deep and it is economically unviable to use this type of foundation. This reason motivated the current study, which aims to evaluate solutions for the installation of helical piles anchored in soil with low capacity. In this research, it was evaluated two alternative solutions to improve the helical pile capacity. The first alternative is injecting a water/ cement mixture which is delivered to the ground throught holes, placed between the upper and bottom helices. The second alternative solution is helical piles with a mortar shaft. Nine pile load tests were performed for the present investigation (five in tension and four in compression): three on conventional helical piles, four on helical piles with injection, and two on helical piles with mortar shaft. After that, the helical piles were exhumed for the verification of the shaft shape and the forms of the bulbs resulting from injections performed with cement mixture. The results of these tests indicated that the uplift capacity of helical piles can be increased by using the alternatives tested. However, more tests are needed to evaluate the effectiveness of these procedures, in different soil conditions and pile configurations.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-12-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.